Key result
Post-TAVR bioprosthetic valve failure is linked to ~72% higher all-cause mortality.
Why the study?
As TAVR expands to younger, lower-risk patients, data on the long-term incidence, predictors, and clinical impact of VARC-3 defined bioprosthetic valve failure after TAVR remain limited.
What is the long-term incidence, predictors, and clinical impact of bioprosthetic valve failure (BVF) in patients undergoing transcatheter aortic valve replacement (TAVR)?
Cohort (n=7,501)
Yes
What is the long-term incidence, predictors, and clinical impact of bioprosthetic valve failure (BVF) in patients undergoing transcatheter aortic valve replacement (TAVR)?
Bioprosthetic valve failure occurs in 8.0% of patients at 10 years post-TAVR and is independently associated with significantly higher risks of mortality, stroke, and heart failure hospitalization, underscoring the need for tailored long-term surveillance.
Extended surveillance after TAVR may be warranted; leaves open randomized trials on prevention to reduce associated mortality and heart failure.
Background A comprehensive understanding of the incidence, mechanisms, and clinical consequences of bioprosthetic valve dysfunction after transcatheter aortic valve replacement (TAVR) is increasingly needed given the expansion of indications toward younger and lower-risk patients with longer life expectancy. The Valve Academic Research Consortium-3 (VARC-3) has introduced the concept of bioprosthetic valve failure (BVF) as a patient-oriented clinical endpoint that integrates the downstream consequences of bioprosthetic valve dysfunction, irrespective of its underlying mechanism. However, data on the long-term incidence and clinical impact of BVF after TAVR remain limited. Purpose To assess the incidence, predictors, and clinical impact of BVF following TAVR. Methods We analyzed the data of an international, multicenter registry including patients undergoing TAVR at 13 centers. The primary outcome was BVF according to VARC-3 criteria. The cumulative incidence of BVF was estimated using a competing risk approach. The association between BVF and clinical outcomes was assessed using multivariable Cox models with BVF as a time-dependent covariate. Results Among 7,501 patients, BVF occurred in 380 patients (5.1%) over a median follow-up of 4 (IQR 2-5) years. The cumulative incidence of BVF increased over time, reaching 1.4% at 1 year, 4.5% at 5 years, and 8.0% at 10 years. Independent predictors of BVF included younger age, balloon-expandable valve, prosthesis size <26 mm, valve-in-valve procedure, mean gradient at discharge ≥15 mmHg, moderate or severe AR at discharge, and early hemodynamic valve deterioration (Table 1). BVF was independently associated with an increased risk of all-cause mortality (adjusted hazard ratio (aHR) 1.72 [95% CI, 1.48-2.01], p<0.001), cardiovascular mortality (aHR 2.68 [95% CI, 2.15-3.34], p<0.001), stroke (aHR 1.88 [95% CI, 1.12-3.14], p=0.016) and heart failure hospitalization (aHR 1.74 [95% CI, 1.20-2.51], p=0.003) (Figure 1). Consistent findings were observed in different sensitivity analyses. Conclusions In this study, the 10-year cumulative incidence of BVF following TAVR was 8.0%. BVF was associated with adverse clinical outcomes during follow-up, including increased risks of death, stroke and heart failure hospitalization. These findings underscore that BVF is not merely a structural or hemodynamic endpoint, but a clinically meaningful event with important implications for patient prognosis. These results support the implementation of tailored surveillance and preventive strategies to mitigate BVF-related risk.
No takes yet. Share an insight, caveat, or question.
Trimaille et al. (2026) conducted a cohort in Patients undergoing transcatheter aortic valve replacement (TAVR) (n=7,501). Transcatheter aortic valve replacement (TAVR) / Bioprosthetic valve failure (BVF) vs. No bioprosthetic valve failure was evaluated on Bioprosthetic valve failure (BVF) according to VARC-3 criteria (and its association with all-cause mortality) (aHR 1.72, 95% CI 1.48-2.01, p=<0.001). Bioprosthetic valve failure after TAVR reached an 8.0% 10-year cumulative incidence and increased all-cause mortality risk (aHR 1.72; 95% CI 1.48-2.01; p<0.001).