Key result
Post-TAVR bioprosthetic valve failure is linked to ~72% higher all-cause mortality.
Why the study?
Data on the long-term incidence and clinical impact of bioprosthetic valve failure after transcatheter aortic valve replacement remain limited.
Does bioprosthetic valve failure increase the risk of adverse clinical outcomes in patients who underwent transcatheter aortic valve replacement?
Cohort (n=7,501)
Yes
Does bioprosthetic valve failure increase the risk of adverse clinical outcomes in patients who underwent transcatheter aortic valve replacement?
Bioprosthetic valve failure after transcatheter aortic valve replacement is a clinically relevant event that increases over time and is strongly associated with increased mortality, stroke, and heart failure hospitalization.
Highlights the prognostic importance of long-term surveillance after TAVR; leaves.
BACKGROUND: Data on the long-term incidence and clinical impact of bioprosthetic valve failure (BVF) after transcatheter aortic valve replacement remain limited. This study aimed to assess the incidence, predictors, and clinical impact of BVF following transcatheter aortic valve replacement. METHODS: We analyzed data from an international, multicenter registry including consecutive patients undergoing transcatheter aortic valve replacement at 13 centers. The primary outcome was BVF according to Valve Academic Research Consortium-3 criteria. The cumulative incidence of BVF was estimated using a competing-risk approach. The association between BVF and clinical outcomes was assessed using competing-risk models with BVF as a time-dependent covariate. RESULTS: Among 7501 patients, BVF occurred in 380 (5.1%) patients over a median follow-up of 4 (interquartile range, 2–5) years. The cumulative incidence of BVF increased over time, reaching 1.4% at 1 year, 4.6% at 5 years, and 8.3% at 10 years. Independent predictors of BVF included younger age, smoking, balloon-expandable valve, prosthesis size <26 mm, valve-in-valve procedure, mean gradient at discharge ≥15 mm Hg, moderate or severe aortic regurgitation at discharge, and early hemodynamic valve deterioration. BVF was independently associated with an increased risk of all-cause mortality (adjusted hazard ratio, 1.72 [95% CI, 1.47–2.01]; P <0.001), cardiovascular mortality (adjusted hazard ratio, 3.23 [95% CI, 2.73–3.82]; P <0.001), stroke (adjusted hazard ratio, 2.08 [95% CI, 1.02–4.23]; P =0.043), and heart failure hospitalization (adjusted hazard ratio, 1.43 [95% CI, 1.03–1.98]; P =0.032). Consistent findings were observed in different sensitivity analyses. CONCLUSIONS: BVF is a clinically relevant event associated with adverse long-term outcomes. These findings support the implementation of tailored surveillance and preventive strategies to mitigate BVF-related risk.
No takes yet. Share an insight, caveat, or question.
Trimaille et al. (2026) conducted a cohort in Transcatheter aortic valve replacement (n=7,501). Transcatheter aortic valve replacement was evaluated on Bioprosthetic valve failure according to Valve Academic Research Consortium-3 criteria. Following transcatheter aortic valve replacement, bioprosthetic valve failure occurred in 5.1% of patients over a median 4 years and was associated with increased all-cause mortality (HR 1.72).