Key result
Discharge echocardiography estimates ~8 mmHg higher post-TAVI mean gradients than invasive measurements.
Why the study?
Discordance between higher discharge echocardiographic transvalvular mean pressure gradients and intraoperative invasive measurements after TAVI is incompletely understood and may cause misinterpretation of valve performance and unwarranted re-interventions.
Does simultaneous assessment and pharmacological flow modulation with dobutamine explain the discordance between invasive and echocardiographic transvalvular mean pressure gradients in patients undergoing TAVI?
Observational (n=34)
Does simultaneous assessment and pharmacological flow modulation with dobutamine explain the discordance between invasive and echocardiographic transvalvular mean pressure gradients in patients undergoing TAVI?
Simultaneous assessment and accounting for differences in transvalvular flow substantially reduces the observed overestimation of transvalvular mean pressure gradients by discharge echocardiography compared to post-TAVI invasive measurements.
Answers are grounded in this paper and cite their sources.
Discharge echo MG may overestimate post-TAVI gradients versus immediate invasive measures; leaves open optimal assessment timing and modality in prospective studies.
Background Echocardiography at discharge frequently estimates higher transvalvular mean pressure gradients (MG) compared to intraoperative invasive measurements following transcatheter aortic valve implantation (TAVI). This discordance is incompletely understood and may lead to misinterpretation of valve performance and unwarranted invasive procedures and re-interventions. Purpose To assess the extent of discordance between invasive intraoperative pressure gradients and echocardiography-derived pressure gradients. Furthermore, to test the hypothesis that procedural interventions such as conscious sedation and rapid pacing may reduce transvalvular flow during the TAVI-procedure and hence explain the discordance. Methods In this prospective study, 34 patients underwent simultaneous invasive and transthoracic echocardiographic pressure gradient measurements. Assessment of simultaneous gradients was performed immediately after TAVI, both at baseline and during pharmacologically increased flow using dobutamine. Echocardiography was repeated the following day (discharge). Results Echocardiographic MG at discharge was significantly higher than invasive MG measured immediately post-TAVI (12 ± 4 mmHg vs. 4 ± 3 mmHg, p < 0.001; mean difference 8 ± 5 mmHg). In contrast, simultaneous measurements immediately post-TAVI reduced, but did not eliminate the discordance (mean difference 3 ± 4 mmHg, p < 0.001). Dobutamine infusion increased both echocardiographic and invasive MG (8 ± 5 to 13 ± 4 mmHg and 4 ± 3 to 8 ± 5 mmHg, respectively, both p < 0.001). Echocardiographic MG was similar during dobutamine infusion and at discharge (13 ± 4 vs. 12 ± 4, p = 0.24). A representative patient example is shown in the Figure. Conclusion Echocardiography systematically overestimates transvalvular mean pressure gradients compared with invasive measurements after TAVI, but simultaneous assessment substantially reduced the discordance. This may be explained by differences in transvalvular flow.
No takes yet. Share an insight, caveat, or question.
Hovde et al. (2026) conducted an observational in Aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) (n=34). Transthoracic echocardiographic mean pressure gradient measurement (simultaneous post-TAVI, during dobutamine infusion, and at discharge) vs. Invasive intraoperative mean pressure gradient measurement immediately post-TAVI was evaluated on Transvalvular mean pressure gradient (MG) in mmHg (MD 8 mmHg, p=<0.001). Discharge echocardiography estimated higher mean pressure gradients than post-TAVI invasive measurements, while simultaneous measurements reduced discordance.
Synapse has enriched 10 related papers. Consider them for comparative context: