Key result
FFR grey-zone status is linked to ~4.5-fold higher odds of discordance with QFR.
Why the study?
Quantitative flow ratio (QFR) provides a wire-free alternative to fractional flow reserve (FFR) for physiologic lesion assessment, but the determinants of clinically relevant discordance between QFR and FFR remain incompletely defined.
Does lesion length interact with borderline (grey-zone) fractional flow reserve physiology to influence diagnostic discordance between angiography-based quantitative flow ratio and fractional flow reserve in a real-world cohort of coronary lesions?
Cohort (n=76)
Does lesion length interact with borderline (grey-zone) fractional flow reserve physiology to influence diagnostic discordance between angiography-based quantitative flow ratio and fractional flow reserve in a real-world cohort of coronary lesions?
Answers are grounded in this paper and cite their sources.
While angiography-based QFR shows moderate overall agreement with invasive FFR, diagnostic discordance is substantially higher in borderline grey-zone lesions (FFR 0.75-0.85) and is further amplified by longer lesion length.
Background Fractional flow reserve (FFR) remains the reference standard for invasive physiologic lesion assessment. Quantitative flow ratio (QFR) provides a wire-free alternative; however, determinants of clinically relevant discordance remain incompletely defined. Purpose To evaluate agreement between QFR and FFR and determine whether lesion length and grey-zone physiology interact to influence discordance. Methods Seventy-six lesions with available FFR measurements were included in the comparative analysis. Hemodynamic significance was defined as FFR ≤0.80 and QFR ≤0.80. Correlation and categorical agreement were calculated. Discordance was modeled using penalized logistic regression lesion length (per 10 mm), FFR grey-zone status (0.75–0.85), and their interaction. Results QFR correlated with FFR (r=0.57, p= 0.000000094) with 82.9% agreement (κ=0.61). Overall discordance occurred in 17.1% of lesions. Grey-zone lesions demonstrated substantially higher discordance rates. In penalized logistic regression (n=73), grey-zone status was associated with a 4.5-fold higher odds of QFR–FFR discordance (OR 4.50). An interaction between lesion length and grey-zone status was observed, with increasing lesion length amplifying discordance specifically in borderline lesions (interaction OR 1.18 per 10 mm). Conclusions In an expanded real-world cohort, QFR shows moderate agreement with FFR; however, physiologic discordance is strongly influenced by borderline FFR values. Lesion length amplifies discordance predominantly within the grey zone, suggesting that anatomic complexity modulates angiography-based physiologic assessment in intermediate lesions.
No takes yet. Share an insight, caveat, or question.
Marakas et al. (2026) conducted a cohort in Coronary artery lesions (n=76). Quantitative flow ratio (QFR) and FFR grey-zone status (0.75–0.85) vs. Fractional flow reserve (FFR) reference standard / non-grey-zone lesions was evaluated on QFR–FFR discordance (hemodynamic significance defined as FFR ≤0.80 and QFR ≤0.80) (OR 4.50, p=0.000000094). Quantitative flow ratio showed 82.9% agreement with FFR, while FFR grey-zone status increased QFR–FFR discordance with lesion length amplification.