Key result
Intracoronary bolus adenosine yields clinically equivalent FFR values compared to intravenous adenosine.
Why the study?
Intracoronary bolus injection of adenosine for FFR assessment is better tolerated, cheaper, and faster than standard intravenous infusion, but existing literature on their equivalence was fragmented and modestly sized.
Meta-Analysis
Supports intracoronary bolus as a practical FFR alternative to intravenous adenosine; confirms their agreement in meta-analysis.
BACKGROUND: Intravenous infusion of adenosine is considered standard practice for fractional flow reserve (FFR) assessment but is associated with adverse side-effects and is time-consuming. Intracoronary bolus injection of adenosine is better tolerated by patients, cheaper, and less time-consuming. However, current literature remains fragmented and modestly sized regarding the equivalence of intracoronary versus intravenous adenosine. We aim to investigate the relationship between intracoronary adenosine and intravenous adenosine to determine FFR. METHODS: We performed a lesion-level meta-analysis to compare intracoronary adenosine with intravenous adenosine (140 µg/kg per minute) for FFR assessment. The search was conducted in accordance to the Preferred Reporting for Systematic Reviews and Meta-Analysis statement. Lesion-level data were obtained by contacting the respective authors or by digitization of scatterplots using custom-made software. Intracoronary adenosine dose was defined as; low: <40 µg, intermediate: 40 to 99 µg, and high: ≥100 µg. We documented a nonclinically relevant mean difference of 0.006 (limits of agreement: -0.066 to 0.078) between the methods. When stratified by the intracoronary adenosine dose, mean differences between intracoronary and intravenous-FFR amounted to 0.004, 0.011, or 0.000 FFR units for low-dose, intermediate-dose, and high-dose intracoronary adenosine, respectively. CONCLUSIONS: The present study documents clinically irrelevant differences in FFR values obtained with intracoronary versus intravenous adenosine. Intracoronary adenosine hence confers a practical and patient-friendly alternative for intravenous adenosine for FFR assessment.
No takes yet. Share an insight, caveat, or question.
Wijntjens et al. (2019) conducted a meta-analysis in Coronary artery disease undergoing fractional flow reserve assessment. Intracoronary bolus injection of adenosine vs. Intravenous infusion of adenosine (140 µg/kg per minute) was evaluated on Fractional flow reserve (FFR) value difference (MD 0.006, p=<0.001). Intracoronary bolus adenosine showed a nonclinically relevant mean difference of 0.006 FFR units (limits of agreement: -0.066 to 0.078) compared with intravenous adenosine.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: