Key result
Intracoronary adenosine produced equivalent Fractional Flow Reserve measurements compared to intravenous adenosine with fewer systemic adverse events.
Why the study?
Does intracoronary adenosine provide equivalent FFR measurements compared to intravenous adenosine in patients with intermediate focal coronary lesions?
Observational (n=50)
No
Does intracoronary adenosine provide equivalent FFR measurements compared to intravenous adenosine in patients with intermediate focal coronary lesions?
Intracoronary adenosine is equivalent to intravenous infusion for determining FFR, while offering better tolerability and fewer systemic adverse events.
Answers are grounded in this paper and cite their sources.
May support intracoronary adenosine for FFR due to equivalent values and fewer events; leaves open need for randomized confirmation.
BACKGROUND: Fractional Flow Reserve (FFR), a measure of coronary stenosis severity is based on the achievement of maximal hyperemia of coronary microcirculation. The most widely used pharmacological agent is adenosine which is administered either by intra coronary or intra venous routes. IV route is time consuming, has more side effects and expensive. This study is undertaken to compare the two routes of administration. METHODS: FFR was assessed in 50 patients with 56 intermediate focal lesions using both IV and intracoronary (IC) adenosine. FFR was calculated as the ratio of the distal coronary pressure to the aortic pressure at maximal hyperemia. RESULTS: A total of 25 left anterior descending, 8 right, 21 circumflex, and 2 left main coronary arteries were evaluated. The mean percent stenosis was 63.91 ± 13.13 SD and, the mean FFR was 0.831 ± 0.0738 SD for IV and 0.832 ± 0.0707 SD for IC adenosine. There was a strong and linear correlation between 2 sets of observations with IV dose and IC adenosine dose (R = 0.964, y = 0.065 + 0.923x; p < 0.001) (y = IV dose, x = IC dose). The agreement between the two sets of measurements was also high, with a mean difference of: 0.001 ± 0.0197. The changes in heart rate and blood pressure were significantly higher in IV adenosine group. Different incremental doses were well tolerated, with fewer systemic adverse events with IC adenosine. Transient AV blocks were observed with both IV and IC adenosine. CONCLUSIONS: This study suggests that IC adenosine is equivalent to IV infusion for the determination of FFR. The administration of IC adenosine is easy to use, cost effective, safe and associated with fewer systemic events.
No takes yet. Share an insight, caveat, or question.
Sandhu et al. (2013) conducted an observational in Coronary artery disease with intermediate stenosis (n=50). Intracoronary adenosine vs. Intravenous adenosine (140, 160, 180 mg/kg/min) was evaluated on Mean Fractional Flow Reserve (FFR) (Mean difference 0.001). Intracoronary adenosine produced equivalent Fractional Flow Reserve measurements compared to intravenous adenosine with fewer systemic adverse events.
Synapse has enriched 10 related papers. Consider them for comparative context: