Key result
Expanding INR self-monitoring to 50% market share saves ~€184 million over 5 years.
Why the study?
Patient self-testing and patient self-management might provide better coagulation care than monitoring at specialized anticoagulation centers, yet this strategy remains underused in the Netherlands.
Answers are grounded in this paper and cite their sources.
Budget-impact analysis reveals expanding patient self-management saves healthcare costs in long-term anticoagulation, suggesting substantial economic benefits except in atrial fibrillation.
BACKGROUND: Patient self-testing (PST) and/or patient self-management (PSM) might provide better coagulation care than monitoring at specialized anticoagulation centers. Yet, it remains an underused strategy in the Netherlands. METHODS: Budget-impact analyses of current and new market-share scenarios of PST and/or PSM compared with monitoring at specialized centers were performed for a national cohort of 260,338 patients requiring long-term anticoagulation testing. A health care payer perspective and 1- to 5-year time horizons were applied. The occurrence of thromboembolic and hemorrhagic complications in the aforementioned patient population was assessed in a Markov model. Dutch-specific costs were applied, next to effectiveness data derived from a meta-analysis on PST and/or PSM. Sensitivity and scenario analyses were performed to assess uncertainty on budget-impact analysis results. RESULTS: Increasing PST and/or PSM usage in the national cohort from the current 15.4% to 50% resulted in savings ranging from €8 million after the first year to €184 million after 5 years. Further increases in the use of PST and/or PSM produced greater savings. Sensitivity analyses revealed budget-impact model sensitivity to the baseline and relative risks of thromboembolic complications. Unfavorable budget impact was found in scenarios exploring an increase in the use of PST alone as well as an increase in the market share of PST and PSM in patients with atrial fibrillation. CONCLUSIONS: Overall study findings indicated that PST and PSM are more favorable alternatives to monitoring at specialized centers in patients without atrial fibrillation.
No takes yet. Share an insight, caveat, or question.
Stevanović et al. (2016) studied Patients requiring long-term anticoagulation testing (n=260,338). Patient self-testing (PST) and/or patient self-management (PSM) vs. Monitoring at specialized anticoagulation centers was evaluated on Budget impact (health care payer savings over 1 to 5 years). Increasing patient self-testing and self-management market share from 15.4% to 50% saved €8 million at 1 year and €184 million at 5 years compared with specialized center monitoring.
Synapse has enriched 10 related papers. Consider them for comparative context: