Student BAJA SAE vehicles rarely carry instrumen-tation, so slow failures such as CVT overheating and brake fadeare diagnosed from driver memory after a run. This paperpresents a low-cost data logger built for the Team RedShiftRacing India vehicle and reports how far each part has beenvalidated. Two Arduino Uno R4 sensor nodes and a receivershare a 500 kbps CAN bus carrying eight identifiers; a RaspberryPi 4 logs the stream, drives a cockpit display, runs an offlinecleaning and machine-learning pipeline and uploads data througha SIM7600G-H LTE modem to a web dashboard. On three vehiclesessions the first logger recorded 3.31, 3.32 and 1.99 Hz with atmost 0.68 % rate error, 99.31 to 100 % completeness and under0.7 MB/h storage growth, but its 1.45 to 1.8 ms jitter failed the1 ms limit; the revised logger ran at 10.0 Hz with at most 0.12 msjitter. The calculated worst-case bus load is 1.19 %. In bench teststhe two brake-pressure channels read −0.27 to −0.38 bar at restand agreed within 2.2 % over 23 applications (r = 0.9983). Of28 tests fixed in advance, 8 pass, 4 pass in part, 1 fails and 15remain open, chiefly live streaming from the moving car andaccuracy against reference instruments.
No takes yet. Share an insight, caveat, or question.
Modi et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: