Key result
Impedance cardiography cepstral analysis accurately identifies mitral stenosis confirmed against catheterization and echo-Doppler.
Why the study?
This study aimed to describe a non-invasive method for quantifying serious and very serious mitral stenosis using discriminant analysis of cepstral parameters from impedance cardiography signals.
Does discriminant analysis of cepstral parameters from impedance cardiography accurately identify serious and very serious mitral stenosis compared to conventional methods?
Observational (n=62)
Does discriminant analysis of cepstral parameters from impedance cardiography accurately identify serious and very serious mitral stenosis compared to conventional methods?
Discriminant analysis of cepstral parameters from impedance cardiography signals offers a potential non-invasive method to quantify and confirm serious mitral stenosis.
Answers are grounded in this paper and cite their sources.
May support non-invasive mitral stenosis detection via cepstral analysis; leaves open prospective validation in larger cohorts against catheterization.
The diagnosis of cardiovascular diseases could be performed by several invasive and non-invasive methods. A non-invasive method for cardiac diseases quantification is described in this paper. Our method uses discriminant analysis of seven cepstral parameters computed from the Impedance cardiography signal (ICG) which represents an impedance variation in explored thoracic region at the level of the ascending aorta. In this study we have performed the assessment of two kinds of serious mitral stenosis (MS++) and very serious (MS+++) disease.. These diseasesare already well known by conventional methods (cardiovascular catheterization and echo-Doppler methods). A data base of 62 subjects (10 normal and 52 with different kinds of cardiac diseases) is used. The sample of the mitral stenosis diseases is constituted by six cases. Results show that the fisher distances(dij) of mitral stenosis diseasesare minimum which represents a confirmation of the nature of these diseases. These results are confirmed by Stewart Hamilton dilution method and Cardiac Echo-Doppler method.
No takes yet. Share an insight, caveat, or question.
Tareq Hadidi (2017) conducted an observational in Mitral stenosis (serious MS++ and very serious MS+++) and other cardiac diseases (n=62). Discriminant analysis of seven cepstral parameters from Impedance Cardiography (ICG) vs. Conventional methods (cardiovascular catheterization, Stewart Hamilton dilution method, and Cardiac Echo-Doppler) was evaluated on Fisher distances (dij) of mitral stenosis diseases for diagnostic confirmation. Impedance cardiography cepstral analysis yielded minimal Fisher distances across 6 mitral stenosis cases (N=62 total), confirming diagnoses against catheterization and echo-Doppler.
Synapse has enriched 10 related papers. Consider them for comparative context: