Key result
Bioimpedance cepstral analysis classifies 25 cardiac conditions with ~95% diagnostic accuracy.
Why the study?
Noninvasive automatic diagnosis of cardiovascular anomalies is needed for emergency cases, children, the elderly, and pregnant women who cannot tolerate cardiac surgical procedures. This study developed an automatic diagnostic method based on bioimpedance signal processing and cepstral parameter classification.
Answers are grounded in this paper and cite their sources.
Bioimpedance-based automatic diagnosis may aid noninvasive cardiac assessment; leaves open validation and accuracy in larger prospective studies before clinical use.
The objective of this work is to perform automatic diagnosis using a non invasive method which consists on the bioimpedance signal processing. Bioimpedance signal (BIS) represents the aorta impedance variation during the heart cycle activity. BIS is detected by mean of two electrodes located at the level of the ascendant aorta. Automatic diagnosis method consists on preparing, first, a data base with a set of cepstral parameters of different BIS according to normal case and different cardiac diseases. This data base is composed from n classes Yk corresponding to n diseases. The classification of anonymous individuals is based on the determination of Fisher distance between anonymous disease and class Yk using Fischer formula. Our method permits to calculate seven relevant cepstral parameters. The application of Fisher method has allowed us to perform the diagnosis of five anonymous cases. The major interest of this method is its especially useful for the exploration of cardiovascular system anomalies for emergency cases, children, elderly and pregnant women who can’t support surgical operations especially at the level of the heart.
No takes yet. Share an insight, caveat, or question.
Salah et al. (2015) studied Cardiovascular diseases (including aortic and mitral valve diseases, pulmonary stenosis, septal defects, and cardiomyopathy) (n=25). Bioimpedance signal cepstral analysis using 7 cepstral parameters and Fisher discriminant analysis vs. 15 bioimpedance parameters (temporal, spectral, and cepstral) and Echo-Doppler confirmation was evaluated on Correct diagnostic classification across 25 cardiovascular classes. Bioimpedance signal analysis using 7 cepstral parameters and Fisher discriminant analysis achieved 95.40% correct classification across 25 cardiac classes and diagnosed 3 test cases.
Synapse has enriched 10 related papers. Consider them for comparative context: