Key result
3D TOE and CT optimize visualization of right atrial thrombus in heart transplant recipients.
Why the study?
This case illustrates the added value of 3D TEE and CT imaging in visualizing right heart thrombi when MRI-incompatible pacemaker or ICD leads are present.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
Demonstrates 3D echocardiography and CT visualization of right atrial thrombus alongside defibrillator leads in a transplant recipient, highlighting imaging utility when MRI is contraindicated.
A heart transplantation patient with vasculopathy carrying an internal cardiodefibrillator (ICD) was referred for retransplantation investigations. Computed tomography (CT) (A) demonstrated a mural thrombus (*) in the right atrium (RA). Transoesophageal echocardiography (TEE) confirmed the thrombus (B). Three-dimensional (3D) reconstructions of TEE (C) and CT (D) images offer a detailed view of the thrombus with relation to the ICD-leads (arrows) and the RA wall. Warfarin therapy was started and the patient is awaiting retransplantation. This case demonstrates the added value of 3D TEE and CT imaging in the visualization of right heart thrombi in the presence of magnetic resonance imaging incompatible pacemaker or ICD-leads.
No takes yet. Share an insight, caveat, or question.
Franssen et al. (2011) conducted a case report in Right atrial thrombus in a heart transplant patient with vasculopathy and an internal cardiodefibrillator (ICD) (n=1). Three-dimensional (3D) transoesophageal echocardiography (TEE) and computed tomography (CT) was evaluated on Visualization of right atrial mural thrombus in relation to ICD leads and right atrial wall. 3D transoesophageal echocardiography and CT imaging provided detailed visualization of a right atrial mural thrombus and ICD leads in 1 heart transplant patient.
Synapse has enriched 10 related papers. Consider them for comparative context: