Retrospective study reveals Doppler flow exceeds device-estimated flow during LVAD implantation across speeds, suggesting probe measurements can refine perioperative pump settings.
All articles of this category (opens in new window) Background: In fully magnetically levitated left ventricular assist devices (LVAD), blood flow is estimated by the device based on power consumption and blood viscosity. This study aimed to compare intraoperative Doppler flow measurements with device-provided flow values displayed on the device monitor. Methods: Twenty consecutive patients who underwent LVAD implantation with intraoperative Doppler-guided flow optimization between January and April 2025 were retrospectively analyzed. LVAD blood flow was routinely measured with a Doppler probe at the outflow graft after weaning from cardiopulmonary bypass. Measurements were obtained at multiple pump speeds: 4,400, 4,800, 5,200 rpm, and the final optimized speed. Concomitant transesophageal echocardiography was performed to guide optimal pump speed adjustment. Results: In this cohort of 20 patients, 15% were female, the median age was 63 years, and the mean BMI was 28.5 kg/m 2 . Preoperative comorbidities included diabetes (40%), COPD (15%), and CKD (25%). The etiology of heart failure was ischemic cardiomyopathy in 45% and nonischemic cardiomyopathy in 55%; 15% experienced prior cardiac arrest. Preoperative temporary mechanical circulatory support was present in 40%, with 30% bridged using a microaxial flow pump, 5% with ECLS, and 5% with combined ECLS and IABP. Across all speed settings, Doppler-derived flow exceeded device-displayed values by a consistent mean difference of 0.49 to 0.56 L/minutes (range: −0.1 to 1.0, p ≤ 0.001; [ Table 1 ]). Table 1 Pump speed (rpm) Flow probe (L/min) Flow pump (L/min) Mean difference (L/min) p -Value Power (W) Pulsatility index RVOT VTI (cm) 4,400 3.4 ± 0.4 2.9 ± 0.3 0.5695% CI (0.40, 0.70) <0.001 2.8 [2.7; 2.9] 4.6 [3.4; 6.2] 12.8 [10.5; 18.8] 4,800 4.1 ± 0.5 3.5 ± 0.3 0.5595% CI (0.33, 0.77) <0.001 3 [2.9; 3.2] 3.7 [3.3; 4.8] 13 [9.3; 17.2] 5,200 4.7 ± 0.5 4.2 ± 0.3 0.5395% CI (0.31, 0.74) 0.001 3.5 [3.4; 3.6] 3.6 [3.2; 3.9] 14.3 [8.3; 17.5] Optimal (5,300–5,600) 4.9 ± 0.6 4.4 ± 0.4 0.4995% CI (0.23, 0.74 0.001 3.8 [3.6; 3.9] 3.3 [3.1; 3.5] 16.6 [11.7; 24.2] Conclusion: Intraoperative Doppler flow measurement consistently demonstrates higher LVAD flow than device-provided flow estimates displayed on the monitor, with the discrepancy remaining stable across different pump speeds. Doppler flow measurement may serve as a valuable tool for intraoperative evaluation during LVAD implantation and to optimize the postoperative setting. Publication History Article published online: 17 February 2026 © 2026. Thieme. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
No takes yet. Share an insight, caveat, or question.
Stegmann et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: