This is the authors' abstract. We don't add key points for this paper.
The front-row shading reduction coefficient is a key parameter used to calculate the system efficiency of a photovoltaic (PV) power station. Based on the Hay anisotropic sky scattering model, the variation rule of solar radiation intensity on the surface of the PV array during the shaded period is simulated, combined with the voltage–current characteristics of the PV modules, and the shadow occlusion operating mode of the PV array is modeled. A method for calculating the loss coefficient of front shadow occlusion based on the division of the PV cell string unit and Hay anisotropic sky scattering model is proposed. This algorithm can accurately evaluate the degree of influence of the PV array layout, wiring mode, array spacing, PV module specifications, and solar radiation on PV power station system efficiency. It provides a basis for optimizing the PV array layout, reducing system loss, and improving PV system efficiency.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Hu et al. (2022) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: