Key result
Coyote balloon angioplasty for sICAS yields ~95% 30-day procedural success.
Why the study?
Data on the clinical efficacy and safety of the Coyote balloon catheter for treating symptomatic intracranial atherosclerotic stenosis (sICAS) were lacking.
Does elective endovascular angioplasty and stenting using the Coyote balloon catheter achieve acute technical success, 30-day procedural success, and low 6-month restenosis rates in patients with symptomatic intracranial atherosclerotic stenosis?
Observational (n=32)
No
Does elective endovascular angioplasty and stenting using the Coyote balloon catheter achieve acute technical success, 30-day procedural success, and low 6-month restenosis rates in patients with symptomatic intracranial atherosclerotic stenosis?
This first clinical series demonstrates that the Coyote balloon catheter is technically feasible for treating symptomatic intracranial atherosclerotic stenosis, achieving 100% acute technical success, 94.9% 30-day procedural success, and a 7.9% 6-month restenosis rate.
Answers are grounded in this paper and cite their sources.
Supports Coyote balloon use in intracranial stenosis; hypothesis-generating and requires randomized trials before practice change.
Data on the clinical efficacy and safety of the Coyote balloon catheter for symptomatic intracranial atherosclerotic stenosis (sICAS) are lacking. This study reports preliminary findings from the first clinical series evaluating this device, with the aim of describing procedural outcomes and 6-month restenosis rates. This retrospective study included 32 patients (39 lesions) who underwent elective endovascular treatment for sICAS at the Interventional Radiology unit of our institution between July 2024 and December 2025. The primary endpoints were acute technical success (successful device delivery, residual stenosis < 50%, and TICI 2b/3 flow) and 30-day procedural success (technical success without 30-day stroke or death). Secondary endpoints included 6-month restenosis and 1-year target-vessel stroke. The stroke rate during the first month was 5.1% per procedure (6.3% per patient). At 6-month follow-up, restenosis was observed in 7.9% of lesions. Technical success was achieved in 100% of lesions, with all cases obtaining TICI 2b/3 distal perfusion. The mean degree of stenosis significantly decreased from 88.08% preoperatively to 30.12% postoperatively (p < 0.001). The perioperative complication rate was 2.6%. The 30-day procedural success rate was 94.9%, as minor periprocedural strokes occurred in 2 cases (5.1%). This clinical series demonstrates that the Coyote balloon catheter is technically feasible in sICAS with a favorable safety profile. The observed restenosis and stroke rates indicate a viable option for intracranial angioplasty, providing descriptive data for future prospective investigations. Clinical series: Evaluation of the Coyote balloon catheter in sICAS treatment.High technical success: Achievement of 100% technical success and luminal clearance in complex lesions.High safety profile: Low perioperative complications and per-procedure stroke rate.Low restenosis risk: A restenosis rate of 7.9% at the 6-month follow-up suggests favorable mid-term durability. Clinical series: Evaluation of the Coyote balloon catheter in sICAS treatment. High technical success: Achievement of 100% technical success and luminal clearance in complex lesions. High safety profile: Low perioperative complications and per-procedure stroke rate. Low restenosis risk: A restenosis rate of 7.9% at the 6-month follow-up suggests favorable mid-term durability.
No takes yet. Share an insight, caveat, or question.
Turgut et al. (2026) conducted an observational in Symptomatic intracranial atherosclerotic stenosis (sICAS) (n=32). Endovascular angioplasty and stenting using the Coyote balloon catheter was evaluated on Acute technical success (successful device delivery, residual stenosis < 50%, and TICI 2b/3 flow) and 30-day procedural success (technical success without 30-day stroke or death) (p=<0.001). Endovascular treatment with the Coyote balloon catheter in sICAS achieved 100% acute technical success, 94.9% 30-day procedural success, and reduced mean stenosis from 88.08% to 30.12%.