Key result
Conduction system pacing shortens QRS duration by ~10 ms vs biventricular pacing without reducing mortality.
Why the study?
This updated systematic review and meta-analysis of randomized controlled trials was conducted to compare conduction system pacing with biventricular pacing for cardiac resynchronization therapy in patients with heart failure.
Does conduction system pacing improve physiological and clinical outcomes compared to biventricular pacing in heart failure patients undergoing cardiac resynchronization therapy?
Meta-Analysis (n=1,152)
Does conduction system pacing improve physiological and clinical outcomes compared to biventricular pacing in heart failure patients undergoing cardiac resynchronization therapy?
Answers are grounded in this paper and cite their sources.
In heart failure patients undergoing cardiac resynchronization therapy, conduction system pacing provides acute electrical resynchronization and 6-month LVEF benefits over biventricular pacing, but lacks established superiority in 12-month LVEF improvement, mortality, or heart failure hospitalization.
This systematic review and meta-analysis compared conduction system pacing (CSP) with biventricular pacing (BVP) for cardiac resynchronization therapy in heart failure. PubMed/MEDLINE, Embase, the Cochrane Central Register of Controlled Trials, and ScienceDirect were searched from inception through 16 May 2026 for randomized trials. Random-effects Mean Difference/Odds Ratio and Peto pooling were performed with Cochrane Risk of Bias 2 and grade assessment and Twelve trials (1,152 patients) were included. CSP shortened QRS duration (mean difference [MD] -10.03 ms, 95% confidence interval [CI] -15.95 to -4.12) and increased absolute left ventricular ejection fraction at 6 months (MD 3.67% points, 95% CI 1.38–5.95). Six-month change was not significantly different (MD 2.07% points, 95% CI -0.66 to 4.80); 12-month improvement favored BVP (MD -3.28% points, 95% CI -5.00 to -1.55). Mortality (risk ratio 0.69, 95% CI 0.33–1.48), heart failure hospitalization (Peto odds ratio 1.05, 95% CI 0.47–2.33), and pneumothorax (Peto odds ratio 1.94, 95% CI 0.20–18.71) did not differ significantly. CSP showed physiological benefits without established clinical superiority. Heterogeneity, small trials, and limited follow-up restrict interpretation. International Prospective Register of Systematic Reviews (PROSPERO), CRD420261413053. Registry: https://www.crd.york.ac.uk/prospero/
No takes yet. Share an insight, caveat, or question.
Hassan et al. (2026) conducted a meta-analysis in Heart failure undergoing cardiac resynchronization therapy (n=1,152). Conduction system pacing (CSP) vs. Biventricular pacing (BVP) was evaluated on QRS duration (MD -10.03 ms, 95% CI -15.95 to -4.12). Conduction system pacing shortened QRS duration vs biventricular pacing (MD -10.03 ms; 95% CI -15.95 to -4.12) without significantly reducing mortality (RR 0.69; 95% CI 0.33-1.48).
Synapse has enriched 10 related papers. Consider them for comparative context: