Background Sonication of explanted implants has improved microbiological detection in implant-associated infections. However, large inter-laboratory variability in sonication protocols limits comparability and clinical interpretability. Thus, a national consensus-driven initiative was launched to standardize the diagnostic sonication process, using current Swiss practice and the published evidence as a foundation. Methods A Delphi-informed process was conducted, including a national protocol survey and a scoping literature review of published sonication workflows, key parameters, and reporting practices. An online consensus meeting followed, with structured item-by-item discussion and anonymous voting (completeness >80% per item; abstentions excluded from percentage calculations). Results Twenty-one laboratories participated in the national survey; four without sonication, and one duplicate response was identified. T Consensus was reached in 8 of 9 domains: sonication frequency (40 kHz, 100%), intensity (0.22 W/cm 2 , 100%), temperature (room temperature, 100%), duration (1 min, 90.5%), fluid (Ringer's solution, 95.5%), pre- and post-sonication vortexing (30 s each, 94.4%), processing within 6 h (87.5%), culture media panel (aerobic blood agar 93.8%, chocolate agar +5% CO 2 100%, thioglycolate broth 100%, anaerobic Schaedler agar +5% sheep blood 87.5%), incubation (14 days, 84.6%), and quantitative reporting (CFU/mL, 100%). In contrast, volume standardization proposal was predominantly rejected (weight-based volume: 33.3% agreement,; minimum-volume rule: 37.5% agreement), reflecting ongoing feasibility and implementation concerns also noted in the literature. Conclusion A national consensus protocol was developed to harmonize sonication-based implant microbiology processing across key technical, handling, culture, incubation, and reporting domains informed by a scoping synthesis of published workflows and an assessment of current Swiss practice, while volume standardization remained open due to operational constraints. This framework now represents a reproducible baseline to facilitate inter-laboratory comparability and places future work in the position of implementation evaluation and evidence-based interpretive thresholds.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Maai et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: