Key result
BE-TAVR increases 30-day moderate-to-severe paravalvular regurgitation ~8.3-fold compared to SAVR across valve generations.
Why the study?
A systematic synthesis of echocardiographic and cardiac remodeling outcomes comparing balloon-expandable TAVR with SAVR across all four SAPIEN-platform randomized trials and valve generations had not been performed.
Does balloon-expandable transcatheter aortic valve replacement (BE-TAVR) affect moderate/severe paravalvular regurgitation and cardiac remodeling compared to surgical aortic valve replacement (SAVR) in patients undergoing aortic valve replacement?
Meta-Analysis (n=4,101)
Does balloon-expandable transcatheter aortic valve replacement (BE-TAVR) affect moderate/severe paravalvular regurgitation and cardiac remodeling compared to surgical aortic valve replacement (SAVR) in patients undergoing aortic valve replacement?
Answers are grounded in this paper and cite their sources.
Compared to SAVR, balloon-expandable TAVR is associated with higher rates of moderate/severe paravalvular regurgitation and persistent left ventricular hypertrophy regardless of valve generation, while contemporary SAPIEN 3/Ultra devices exhibit higher transprosthetic gradients and smaller valve areas than surgery.
Background: Balloon-expandable transcatheter aortic valve replacement (BE-TAVR) via the SAPIEN platform has been evaluated against surgical aortic valve replacement (SAVR) across the surgical risk spectrum in four randomized controlled trials (RCTs). A systematic synthesis of echocardiographic and cardiac remodeling outcomes across all four SAPIEN-platform RCTs and valve generations has not been performed. Objectives: To compare echocardiographic outcomes and cardiac remodeling following BE-TAVR versus SAVR, with prespecified subgroup analysis by valve generation (early-generation SAPIEN/SAPIEN XT versus contemporary-generation SAPIEN 3/SAPIEN 3 Ultra). Methods: Systematic review and meta-analysis of four RCTs (PARTNER 1A, 2A, 3, RHEIA; n=4,101). Risk of bias was assessed using the Cochrane RoB 2 tool. Outcomes were pooled using random-effects models. The primary outcome was moderate/severe paravalvular regurgitation (PVR). Secondary outcomes included mean transprosthetic gradient, aortic valve area (AVA), LV ejection fraction (LVEF), and LV mass index (LVMI). RV function and valvular pathology were exploratory outcomes. Results: BE-TAVR was associated with significantly higher moderate/severe PVR at 30 days (RR 8.33, 95% CI 3.83-18.13) and 1 year (RR 4.02, 95% CI 1.59-10.17), with no significant difference by valve generation at either timepoint (subgroup P = 0.596 and P = 0.204, respectively). A marked valve-generation interaction was identified for transprosthetic hemodynamics (P < 0.0001 at both timepoints): early-generation devices demonstrated lower gradients and larger AVA than SAVR (MD -1.15 mmHg at 30 days; -0.76 mmHg at 1 year), whereas contemporary-generation devices demonstrated higher gradients and smaller AVA (MD +2.08 mmHg at 30 days; +2.13 mmHg at 1 year), with a null pooled estimate obscuring these opposing effects. No between-group difference in LVEF was observed. BE-TAVR was associated with persistently higher LVMI at 30 days (MD +7.49 g/m 2 , 95% CI 4.55-10.43) and 1 year (MD +7.17 g/m 2 , 95% CI 2.73-11.60), alongside higher LV hypertrophy rates (RR 1.35 at 30 days; 1.40 at 1 year; P < 0.01). BE-TAVR was also associated with better preservation of RV function (TAPSE MD +0.66 cm at 30 days; +0.45 cm at 1 year; P < 0.0001) and lower rates of moderate/severe tricuspid and mitral regurgitation at both timepoints. Conclusion: Despite advances in device technology, BE-TAVR remains associated with higher PVR irrespective of valve generation. Contemporary-generation devices carry higher transprosthetic gradients and smaller AVA than SAVR, findings concealed when generations are pooled, while early-generation devices showed the opposite. The sustained LVMI elevation and higher LV hypertrophy rates constitute a prespecified remodeling signal. Future TAVR trials should report echocardiographic outcomes according to valve generation.
No takes yet. Share an insight, caveat, or question.
Ebeid et al. (2026) conducted a meta-analysis in Aortic valve disease requiring replacement (n=4,101). Balloon-expandable transcatheter aortic valve replacement (BE-TAVR) via the SAPIEN platform vs. Surgical aortic valve replacement (SAVR) was evaluated on Moderate/severe paravalvular regurgitation (PVR) at 30 days (RR 8.33, 95% CI 3.83-18.13). BE-TAVR increased moderate/severe paravalvular regurgitation vs SAVR at 30 days and 1 year, regardless of valve generation.
Synapse has enriched 10 related papers. Consider them for comparative context: