Answers are grounded in this paper and cite their sources.
A concept of the Globus-3 spherical tokamak with a “warm” copper electromagnetic system, developed jointly by employees of the JSC NIIEFA and the Ioffe Institute, is presented. By increasing the facility parameters to a plasma current of 2 MA, a toroidal magnetic field of 2 T, and an aspect ratio of 1.8, the expected ion temperature can reach thermonuclear values, which opens up prospects for studying the behavior of charged fusion products, including alpha particles. Using the iterative process, the major and minor plasma radii and the parameters of the poloidal magnetic system of the facility have been determined, allowing for achieving the required discharge plateau duration of up to 3 s. The plasma discharge scenarios are simulated. The choice of scenario parameters is based on data obtained during experiments on the Globus-M2 tokamak, as well as on calculations using the GLOBSYS code. The design variant proposed at this stage is recognized as the most preferable for the implementation of the Globus-3 facility with a copper electromagnetic system in the available experimental building of the Ioffe Institute.
No takes yet. Share an insight, caveat, or question.
Bakharev et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: