Key result
Pentaspline PFA requires ~50% higher adjusted propofol doses under deep sedation than cryoballoon ablation.
Why the study?
Deep sedation is routinely used during single-shot pulmonary vein isolation, but data on sedative requirements and procedural tolerance of pulsed field ablation under deep sedation compared with thermal technologies remain limited.
Does pulsed field ablation using a pentaspline or balloon-in-basket catheter alter sedative requirements, procedural times, and safety under deep sedation compared with cryoballoon ablation in patients undergoing pulmonary vein isolation?
Cohort (n=156)
No
Does pulsed field ablation using a pentaspline or balloon-in-basket catheter alter sedative requirements, procedural times, and safety under deep sedation compared with cryoballoon ablation in patients undergoing pulmonary vein isolation?
Balloon-in-basket pulsed field ablation enables safe pulmonary vein isolation under deep sedation with lower normalized propofol requirements than pentaspline pulsed field ablation and a safety profile comparable to cryoballoon ablation.
Answers are grounded in this paper and cite their sources.
PFA under deep sedation requires higher analgesic doses than cryoballoon; leaves open whether optimized protocols improve tolerance in prospective studies.
Background Deep sedation (DS) is routinely used during single‐shot pulmonary vein isolation (PVI) to optimize patient comfort and procedural stability. However, data on sedative requirements and procedural tolerance of pulsed field ablation (PFA) under DS compared with thermal technologies remain limited. Methods In this single‐center study, consecutive patients underwent PVI with cryoballoon (CB), PFA using a pentaspline catheter (PC) or the balloon‐in‐basket catheter (BC). All procedures were performed under DS with midazolam, fentanyl, and propofol, administered by electrophysiology staff without anaesthesiologist supervision. Propensity score matching (1:1:1) was applied for age, sex, body mass index, and hypertension. Procedural characteristics, sedative/analgesic requirements, and complications were analyzed. Results Acute PVI without major complications was achieved in all 156 enrolled patients. PC procedures were associated with higher body‐weight‐ and time‐adjusted requirements for propofol (CB: 0.10 ± 0.04 mg/kg/min; PC: 0.15 ± 0.04 mg/kg/min; BC: 0.11 ± 0.03 mg/kg/min; p < 0.001) despite the lowest total dose of propofol used (CB: 440 ± 144 mg; PC: 348± 80 mg; BC: 433 ± 160 mg; p = 0.00). Procedural times (CB: 47.5 [40–60] min, PC: 29 [25–35] min, BC: 47.5 [40–56] min, p < 0.001) and fluoroscopy times (CB: 9.5 [6.3–13.6] min; PC: 6.2 [4.4–9] min; BC: 7.2 [6.1–11.2] min, p = 0.001) were shortest in the PC group. Sedation‐related hemodynamic stability was comparable across all cohorts. Conclusions The novel BC demonstrated excellent feasibility under DS, with reduced normalized sedative requirements compared with the PC and a safety profile comparable to CB ablation. These findings suggest that optimized waveform design and field homogeneity may enable safe and comfortable PVI under DS without the need for general anesthesia.
No takes yet. Share an insight, caveat, or question.
Kheir et al. (2026) conducted a cohort in Patients undergoing pulmonary vein isolation (n=156). Pulsed field ablation (pentaspline catheter or balloon-in-basket catheter) vs. Cryoballoon ablation was evaluated on Body-weight- and time-adjusted requirements for propofol (mg/kg/min) (p=<0.001). Pentaspline PFA required higher adjusted propofol doses (0.15 mg/kg/min) under deep sedation than balloon-in-basket PFA (0.11) or cryoballoon (0.10; p<0.001).
Synapse has enriched 10 related papers. Consider them for comparative context: