Key result
Prehospital capillary hs-cTnI accurately identifies NSTEMI with an AUC of ~0.83.
Why the study?
Does prehospital capillary high-sensitivity cardiac troponin I measurement accurately diagnose NSTEMI at hospital discharge in adult patients presenting with acute chest pain?
Observational (n=659)
Treating clinicians blinded to hs-cTnI results
Yes
Does prehospital capillary high-sensitivity cardiac troponin I measurement accurately diagnose NSTEMI at hospital discharge in adult patients presenting with acute chest pain?
Prehospital point-of-care capillary hs-cTnI testing shows good diagnostic accuracy for NSTEMI (AUC 0.83) and high rule-out safety, though routine feasibility is currently limited by unavailable or uninterpretable measurements.
Answers are grounded in this paper and cite their sources.
May support prehospital NSTEMI rule-out with capillary hs-cTnI; leaves open routine feasibility and outcome impact.
BACKGROUND: High-sensitivity cardiac troponin I (hs-cTnI) plays a central role in the diagnosis and management of non-ST-elevation myocardial infarction (NSTEMI), including rule-out and rule-in strategies in the emergency department. Extending hs-cTnI testing to the prehospital setting could accelerate patient orientation and clinical decision-making, but the diagnostic performance of prehospital capillary hs-cTnI remains insufficiently studied. OBJECTIVE: The study aimed to evaluate the diagnostic performance of prehospital capillary hs-cTnI for the diagnosis of NSTEMI at hospital discharge. DESIGN: The study is a prospective multicenter diagnostic accuracy study with blinded index test results. SETTINGS AND PARTICIPANTS: Four French emergency medical service systems with 10 mobile intensive care units. Adult patients presenting with acute chest pain were included. INDEX TEST: Prehospital hs-cTnI measurement using a point-of-care device (Atellica VTLi) on capillary samples. Treating clinicians were blinded to hs-cTnI results. OUTCOME MEASURES AND ANALYSIS: The primary outcome was the diagnostic performance of capillary hs-cTnI for the diagnosis of NSTEMI at hospital discharge. Diagnostic performance was assessed using the area under the receiver operating characteristic curve with 95% confidence intervals (CIs). Clinically relevant thresholds were defined a priori based on predefined safety criteria. MAIN RESULTS: Among 659 patients included in the primary analysis, 71 (10.8%) had NSTEMI. Prehospital capillary hs-cTnI demonstrated good diagnostic performance [area under the curve (AUC) = 0.83, 95% CI = 0.78-0.88]. A rule-out threshold of <2.2 ng/L, evaluated according to prespecified performance criteria, identified 7.1% of patients, with a negative predictive value of 1.00 (95% CI = 0.92-1.00). A rule-in threshold of >43.6 ng/L identified 6.5% of patients, with a positive predictive value of 0.65 (95% CI = 0.51-0.79). In the predefined sensitivity analysis, venous hs-cTnI showed similar diagnostic performance (AUC = 0.84, 95% CI = 0.79-0.89). CONCLUSION: Prehospital capillary hs-cTnI showed good diagnostic performance for NSTEMI, although feasibility in routine practice was challenged by unavailable or uninterpretable measurements. Further external validation is warranted before implementation in prehospital diagnostic pathways.
No takes yet. Share an insight, caveat, or question.
Guénézan et al. (2026) conducted an observational in Acute chest pain / suspected NSTEMI (n=659). Prehospital capillary hs-cTnI measurement (Atellica VTLi point-of-care device) vs. Diagnosis of NSTEMI at hospital discharge was evaluated on Diagnostic performance for NSTEMI at hospital discharge (AUC 0.83, 95% CI 0.78-0.88). Prehospital capillary hs-cTnI showed good diagnostic accuracy for NSTEMI (AUC 0.83; 95% CI 0.78-0.88), achieving an NPV of 1.00 at <2.2 ng/L and a PPV of 0.65 at >43.6 ng/L.
Synapse has enriched 10 related papers. Consider them for comparative context: