Key result
DeepECG-AMI on mobile limb-lead ECGs yields ~48 percentage points higher sensitivity for AMI than cardiologists.
Why the study?
Deep learning models developed on standard 12-lead ECGs can detect AMI, but their diagnostic performance when applied to limb-lead ECGs acquired from mobile devices was uncertain.
Does an AI model applied to mobile limb-lead ECGs improve diagnostic accuracy for detecting acute myocardial infarction compared to cardiologist-interpreted truncated limb-lead and standard 12-lead ECGs in patients referred for coronary angiography?
Observational (n=153)
No
Does an AI model applied to mobile limb-lead ECGs improve diagnostic accuracy for detecting acute myocardial infarction compared to cardiologist-interpreted truncated limb-lead and standard 12-lead ECGs in patients referred for coronary angiography?
An AI model applied without retraining to mobile limb-lead ECGs discriminated acute myocardial infarction with an AUROC of 0.843 and higher sensitivity (88.0% vs. 40.0%) than cardiologist-interpreted 12-lead ECGs at a high-sensitivity threshold, supporting its potential as an adjunctive screening aid when 12-lead ECG or expert reading is unavailable.
Answers are grounded in this paper and cite their sources.
Should not yet change AMI triage; extends 12-lead AI models to mobile ECGs but remains hypothesis-generating in small observational data.
Background Deep learning models developed on standard 12-lead electrocardiograms (ECGs) can detect acute myocardial infarction (AMI), but their performance on limb-lead ECGs from mobile devices is uncertain. We evaluated an artificial intelligence (AI) model applied to mobile limb-lead ECGs for AMI detection, using cardiologist interpretation of truncated limb-lead and 12-lead ECGs as comparators. Methods We performed an analysis of a prospective observational cohort of 153 patients referred for coronary angiography at a Korean tertiary center (September 2022–October 2023). Each patient underwent mobile limb-lead and standard 12-lead ECG acquisition before revascularization. The model was applied without retraining to the mobile ECGs at two thresholds prespecified during model development (high sensitivity, high specificity), and three cardiologists independently interpreted truncated limb-lead and 12-lead ECGs. AMI was diagnosed according to the Fourth Universal Definition of Myocardial Infarction, with coronary angiography in all patients. Results Twenty-five patients (16.3%) had AMI, including 3 ST-elevation and 22 non-ST-elevation myocardial infarctions. The model achieved an area under the receiver operating characteristic curve of 0.843 (95% confidence interval, 0.758–0.928). At the high-sensitivity threshold, the model showed higher sensitivity than cardiologists interpreting truncated limb-lead and standard 12-lead ECGs (88.0% vs. 20.0% and 40.0%; both p < 0.001) and numerically higher negative predictive value (NPV; 95.9% vs. 85.5% and 88.6%), but lower specificity (55.5% vs. 92.2% and 91.4%; both p < 0.001) and positive predictive value (PPV; 27.8% vs. 33.3% and 47.6%). At the high-specificity threshold, specificity was similar to that of cardiologists interpreting standard 12-lead ECGs (93.8% vs. 91.4%; p = 0.58), and sensitivity did not differ significantly (48.0% vs. 40.0%; p = 0.77). Conclusions In this cohort, an AI-ECG model developed on standard ECGs discriminated AMI when applied to mobile limb-lead ECGs without retraining. At the high-sensitivity threshold, it showed higher sensitivity and numerically higher NPV but lower specificity and PPV than cardiologists’ ECG interpretation. These findings support its potential as an adjunctive screening aid where 12-lead ECG acquisition or expert interpretation is delayed or unavailable.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2026) conducted an observational in Acute myocardial infarction (n=153). DeepECG-AMI AI model applied to mobile limb-lead ECGs vs. Cardiologist interpretation of standard 12-lead ECGs and truncated limb-lead ECGs was evaluated on Sensitivity for detecting acute myocardial infarction at the high-sensitivity threshold compared with cardiologist 12-lead ECG interpretation (MD 48.0 percentage points (AUROC 0.843), 95% CI 24.1 to 65.1, p=<0.001). DeepECG-AMI on mobile limb-lead ECGs achieved an AUROC of 0.843 for AMI and higher sensitivity than cardiologist 12-lead ECG interpretation at the high-sensitivity threshold.
Synapse has enriched 10 related papers. Consider them for comparative context: