Key result
3D-TEE maximal ASD diameter correlates best with deployed closure device size compared to 2D imaging.
Why the study?
Unrepaired secundum ASD is the commonest congenital heart disease encountered in adulthood, and the correlation between its three-dimensional size on transesophageal echocardiography and percutaneous closure device size warranted evaluation.
Does three-dimensional transesophageal echocardiography (3D-TEE) correlate better with percutaneous closure device size than 2D echocardiography in patients undergoing transcatheter secundum atrial septal defect closure?
Cohort (n=36)
Does three-dimensional transesophageal echocardiography (3D-TEE) correlate better with percutaneous closure device size than 2D echocardiography in patients undergoing transcatheter secundum atrial septal defect closure?
Answers are grounded in this paper and cite their sources.
Three-dimensional TEE is a reliable imaging modality that provides the strongest correlation with closure device size compared to 2D echocardiography during percutaneous ASD closure.
Unrepaired secundum ASD (atrial septal defect) is the commonest congenital heart disease encountered in adulthood. In this study we try to correlate the three-dimensional size of a secundum ASD to the device size. We did a retrospective analysis to 36 patients who underwent successful transcatheter closure of atrial septal defect guided by balloon sizing and correlated this to the device size. The device size was correlated significantly with all the maximal ASD diameter by 2D-TTE, 2D-TEE and 3D-TEE. However, the most significant correlation was between three-dimensional maximal diameter and device. 3D TEE is a promising and reliable tool that can be used to determine the size, number and shape of ASD and to accurately select the suitable device size during percutaneous closure.
No takes yet. Share an insight, caveat, or question.
Abdelghani et al. (2022) conducted a cohort in Secundum atrial septal defect (n=36). Three-dimensional transesophageal echocardiography (3D-TEE) vs. Two-dimensional transthoracic echocardiography (2D-TTE) and two-dimensional transesophageal echocardiography (2D-TEE) was evaluated on Correlation between maximal atrial septal defect diameter and deployed device size. Three-dimensional TEE maximal ASD diameter showed the most significant correlation with percutaneous closure device size compared to 2D-TTE and 2D-TEE in 36 patients.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: