This study investigates nugget formation, microstructural evolution, and failure mechanisms in dissimilar resistance spot welded (RSW) joints between wrought and selective laser melted (SLM) 316L stainless steels. The SLM material exhibits a hierarchical microstructure consisting of melt-pool boundaries, columnar cellular subgrains, and nanoscale cellular networks, in contrast to the equiaxed austenitic structure of the wrought material. Tensile testing reveals pronounced anisotropy in the SLM material between the building and transverse directions. RSW was performed at currents of 5–9 kA using three joint configurations: wrought/wrought, SLM(B)/wrought, and SLM(T)/wrought. The results show that the nugget develops asymmetrically toward the SLM side, while the columnar dendritic region formed during weld-pool solidification exhibits localized chemical heterogeneity, including Ni enrichment along interdendritic boundaries. The SLM side also contains process-induced defects that influence crack initiation and subsequent fracture. At higher welding currents, the dissimilar joints achieve load capacities comparable to the wrought/wrought joints; however, fracture consistently localizes on the SLM side because of the combined effects of lower ductility and process-induced defects. The results demonstrate that the failure behavior of dissimilar RSW joints is governed by the coupled effects of nugget geometry, weld-solidification microstructure, SLM build orientation, and defect population.