Answers are grounded in this paper and cite their sources.
This simulated study calculates what a wetted sheet hung at an open window does to a small room and to a fevered patient inside it. The room measures 3 m by 4 m by 2.6 m, with 5 air changes per hour passing through a sheet of 2 m². At an outdoor temperature of 35 °C and 30 percent relative humidity, the wet-bulb temperature is 22.1 °C and the room settles at 27.7 °C, a depression of 7.3 °C, while the room humidity rises by 36.5 percentage points and the sheet consumes 0.9 litres of water per hour. The patient's net heat loss improves by 35.0 W in that case despite weaker evaporation from the patient's own skin, because the cooler air restores dry heat loss. At 35 °C and 70 percent humidity the room cools by only 0.8 °C and the patient's net heat loss worsens by 14.7 W. Scanning humidity at 35 °C places the crossing point at 56 percent outdoor relative humidity: above it, the sheet raises the patient's heat stress instead of lowering it. The study is simulated, not measured.
No takes yet. Share an insight, caveat, or question.
William Alexander Aldred (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: