Key result
Undetectable PDA shunting inlet and larger shunt angle predict transvenous PDA closure failure.
Why the study?
The transvenous V-method simplifies transcatheter PDA closure with fewer complications than the arteriovenous method and retrograde transarterial coil occlusion, but it carries variable failure rates. This study aimed to identify preoperative TTE predictors of V-method failure and establish a model to optimize procedural strategies.
Do preoperative transthoracic echocardiography features (specifically shunt angle and detectable shunting inlet) predict the procedural failure of exclusive transvenous (V-method) closure in patients with patent ductus arteriosus?
Observational (n=403)
7:3 random split into training and internal validation cohorts
No
Do preoperative transthoracic echocardiography features (specifically shunt angle and detectable shunting inlet) predict the procedural failure of exclusive transvenous (V-method) closure in patients with patent ductus arteriosus?
Preoperative echocardiographic assessment of PDA shunting inlet visibility and flow-pulmonary shunt angle (≤81.61°) accurately predicts the success of simplified exclusive transvenous PDA closure, enabling tailored procedural planning that avoids unnecessary arterial access and reduces radiation and costs.
Answers are grounded in this paper and cite their sources.
May guide PDA closure planning via echocardiography; leaves open prospective validation before routine adoption.
Background The transvenous V-method simplifies transcatheter patent ductus arteriosus (PDA) closure compared with the arteriovenous (AV) method and retrograde transarterial coil occlusion, with fewer complications, but it carries variable failure rates. This study aimed to identify preoperative transthoracic echocardiography (TTE) predictors for V-method failure and establish a practical model to optimize procedural strategies. Methods A total of 403 consecutive patients undergoing transcatheter PDA closure in Fujian Medical University Union Hospital between October 2014 and July 2019 were retrospectively enrolled and randomly split to training ( n = 282) and internal validation ( n = 121) cohorts at a 7:3 ratio. LASSO regression was performed to screen independent predictors. Model performance was validated via ROC, calibration and decision curve analysis. All patients received standardized 3-year postoperative follow-up. Results Overall, 323 patients completed V-method closure, and 80 converted to the AV-method. The median age was 7 years (6 months-73 years) and an average PDA size of 4.43 mm (1.0mm–14.5 mm). Large shunt angle (defined as shunt beam–PDA inlet plane angle; A larger angle may indicate more perpendicular insertion to the pulmonary artery wall) and undetectable PDA shunting inlet on preoperative TTE were independent predictors of V-method failure. The dual-index model achieved excellent predictive performance with AUCs of 0.933 (training) and 0.910 (validation), along with favorable calibration and clinical net benefit. The optimal cut-off value for the model was defined as an undetectable PDA shunting inlet or a shunt angle > 81.61°, with a sensitivity of 89.5% and a specificity of 96.4%. At 3-year follow-up, no signal of excess harm was detected in either group. Conclusion A small angle of shunting and detectable shunting inlet by echocardiography may predict successful exclusive transvenous PDA closure. The 3-year follow-up suggested the safety and efficacy of the exclusive transvenous access.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2026) conducted an observational in Patent ductus arteriosus (n=403). Undetectable PDA shunting inlet on preoperative TTE (U-echo) vs. Detectable PDA shunting inlet on preoperative TTE was evaluated on Exclusive transvenous (V-method) PDA closure failure (conversion to arteriovenous loop rescue technique) (OR 394.241, 95% CI 72.122-3171.881, p=<0.001). Undetectable PDA shunting inlet and larger shunt angle predicted transvenous PDA closure failure with a validation AUC of 0.910.
Synapse has enriched 10 related papers. Consider them for comparative context: