Key result
Leadless pacemaker implantation achieves ~100% procedural success in patients with Fontan circulation.
Why the study?
Epicardial or transvenous pacing strategies may be suboptimal in some patients with Fontan circulation requiring permanent pacing, and experience with leadless pacing in complex Fontan anatomy remains limited.
Does transatrial or transconduit leadless pacemaker implantation provide a feasible pacing alternative in patients with Fontan circulation and sinus node dysfunction or complete heart block?
Case Report (n=3)
Does transatrial or transconduit leadless pacemaker implantation provide a feasible pacing alternative in patients with Fontan circulation and sinus node dysfunction or complete heart block?
Transatrial or transconduit leadless pacemaker implantation in the pulmonary venous atrium or systemic ventricle is a feasible alternative that may expand pacing options for selected patients with Fontan circulation when conventional epicardial or transvenous strategies are limited.
Answers are grounded in this paper and cite their sources.
May offer a pacing option in Fontan patients with limited venous access; leaves open the need for prospective studies on safety and durability.
Background Epicardial or transvenous pacing strategies may be suboptimal in certain patients with Fontan requiring permanent pacing. Leadless pacing offers an alternative, but experience in complex Fontan anatomy remains limited. Case Summary We report 3 patients with Fontan who underwent transatrial or transconduit leadless pacemaker (LP) implantation. One patient with a lateral tunnel Fontan and sinus node dysfunction underwent successful placement of an AVEIR AR (Abbott) LP in the pulmonary venous atrium. Two patients with Fontan circulation and complete heart block with prior epicardial pacing systems underwent implantation of a Micra AV (Medtronic) LP in the systemic ventricle, with longer follow-up than in prior reports. Conclusions This case series demonstrates leadless pacing in the pulmonary venous, atrial, and systemic ventricular chambers in Fontan circulation, including atrial AVEIR AR implantation and extended follow-up of ventricular Micra AV pacing. These approaches may expand pacing options in selected patients with Fontan when conventional strategies are limited, although long-term outcomes remain unknown.
No takes yet. Share an insight, caveat, or question.
Duncan et al. (2026) conducted a case report in Fontan circulation requiring permanent pacing (sinus node dysfunction or complete heart block) (n=3). Transatrial or transconduit leadless pacemaker implantation (AVEIR AR or Micra AV) was evaluated on Successful placement of leadless pacemaker. Transatrial or transconduit leadless pacemaker implantation (AVEIR AR or Micra AV) was successfully performed in 3 of 3 patients with Fontan circulation requiring permanent pacing.
Synapse has enriched 10 related papers. Consider them for comparative context: