Answers are grounded in this paper and cite their sources.
Background Diastasis recti abdominis (DRA) is characterized by widening of the linea alba without a true fascial defect, but conventional ultrasound primarily provides linear measurements and two-dimensional CT approaches commonly rely on geometric assumptions for volumetric estimates. Whether CT-based three-dimensional visualization reconstruction (3DVR) provides additional quantitative characterization and systematically different measurements remains uncertain. We therefore compared quantitative measurements of DRA obtained using CT-based 3DVR, two-dimensional CT ellipsoid approximation (2D-EA), and ultrasound (US) in an exploratory methodological study. Methods Twenty patients with DRA were included in this exploratory observational methodological comparison. CT-based 3DVR was used to quantify inter-rectus distance (IRD), defect surface area (DSA), non-hernial abdominal wall bulging-space volume (HSV; abbreviation retained from the original dataset), abdominal cavity volume (ACV), and loss of domain (LOD). A two-dimensional CT ellipsoid approximation (2D-EA) was used for comparison, and all participants also underwent ultrasound measurement of IRD. LOD was calculated as HSV/(HSV + ACV) × 100%. Normality of paired differences was evaluated using the Shapiro-Wilk test. Paired t-tests were used when normality was supported, with Wilcoxon signed-rank tests as sensitivity analyses. Exact P values, 95% confidence intervals, Cohen’s dz effect sizes, Pearson correlations, and a Bonferroni-adjusted significance threshold of P < 0.0071 were reported. Results 3DVR yielded higher ACV than 2D-EA (5340.51 ± 818.53 vs. 4497.82 ± 932.28 cm³; mean paired difference, 842.69 cm³; 95% CI, 577.01-1108.36; P < 0.001; Cohen’s dz = 1.484), higher HSV (248.71 ± 128.95 vs. 190.28 ± 107.05 cm³; difference, 58.43 cm³; 95% CI, 27.53–89.33; P = 0.0008; dz = 0.885), and higher IRD (7.88 ± 1.50 vs. 7.59 ± 1.40 cm; difference, 0.29 cm; 95% CI, 0.11–0.47; P = 0.0035; dz = 0.745). LOD did not differ significantly (4.37 ± 2.05% vs. 3.90 ± 1.69%; P = 0.0886). Mean DSA measured by 3DVR was 115.15 ± 27.79 cm². IRD was also higher with 3DVR than with ultrasound (7.88 ± 1.50 vs. 6.82 ± 1.16 cm; difference, 1.06 cm; 95% CI, 0.40–1.72; P = 0.0034; dz = 0.747), whereas the 2D-EA-versus-ultrasound difference did not meet the Bonferroni-adjusted threshold ( P = 0.0314). The paired differences were compatible with normality, and the principal findings were unchanged using the Bonferroni-adjusted threshold of P < 0.0071. Conclusion CT-based 3DVR demonstrated systematic differences in volumetric and linear measurements compared with 2D-EA and ultrasound and provided DSA, which was not obtainable using the ellipsoid approximation. These findings suggest that 3DVR may offer additional three-dimensional anatomical characterization when CT images are available from appropriately justified examinations; however, the approximately 6-hour reconstruction time per case, lack of a reference standard, and absence of clinical-outcome validation currently limit routine implementation. Future studies should prioritize workflow automation, standardized multimodal acquisition, reproducibility testing, and prospective evaluation of whether 3D-derived measurements influence treatment planning or outcomes. Clinical trial number Not applicable.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: