Key result
OCT-AID automated segmentation matches expert consensus on calcified plaque and outperforms interobserver lipid detection.
Why the study?
Algorithms for automated evaluation of intracoronary OCT images are mostly developed and validated on well-curated data sets that may not represent real-world data, so external validation in an unselected consecutive real-world data set was needed.
Does the OCT-AID artificial intelligence algorithm accurately perform automated full-vessel segmentation and plaque quantification compared to manual expert consensus in a real-world cohort of patients undergoing clinically indicated intracoronary OCT?
Observational (n=100)
Blinded expert readers (3 readers blinded to each other's interpretations and to automated analysis results)
No
Does the OCT-AID artificial intelligence algorithm accurately perform automated full-vessel segmentation and plaque quantification compared to manual expert consensus in a real-world cohort of patients undergoing clinically indicated intracoronary OCT?
External validation in a consecutive real-world cohort demonstrates that AI-based automated OCT segmentation achieves plaque identification and quantification performance comparable to or exceeding expert interobserver agreement, supporting its clinical feasibility.
Answers are grounded in this paper and cite their sources.
May support standardized OCT plaque analysis in research; leaves open prospective validation before clinical adoption.
BACKGROUND: Artificial intelligence (AI) allows automated evaluation of intracoronary optical coherence tomography (OCT) images. However, algorithms are mostly developed and validated on well-curated data sets, which may not represent real-world data. We sought to externally validate a previously developed algorithm performing full-vessel segmentation for OCT in an unselected consecutive real-world data set. METHODS: This was a retrospective, single-center, external validation study comprising 100 consecutive patients undergoing clinically indicated OCT. A previously developed AI algorithm (OCT-AID) was used for automated pixelwise labeling of OCT images, distinguishing among lumen, guidewire artifact, intima, media, lipid plaque, calcium plaque, side branch, plaque rupture, thrombus, microvessel, and background. The AI-based predictions were compared on a frame level to the reference standard obtained through manual OCT image analysis by expert readers. RESULTS: Among 2560 analyzable frames, the agreement between the automated OCT image analysis and the reference standard was excellent for calcified plaque identification (κ=0.88 [95% CI, 0.84-0.92]) and quantification (intraclass correlation coefficient values ranged between 0.79 and 0.93), with a performance close to interobserver variability. For lipid plaque identification and quantification, the model performance was reasonable (κ=0.68 [95% CI, 0.64-0.72]; intraclass correlation coefficient for lipid arc, 0.79 [95% CI, 0.76-0.81]; intraclass correlation coefficient for minimum fibrous cap thickness, 0.59 [95% CI, 0.55-0.63]) and largely superior to interobserver variability. The algorithm performance for low-prevalence features (e.g., plaque rupture) was limited. CONCLUSIONS: AI-based fully automated evaluation of OCT images is feasible with performances consistent with interobserver variability in a real-world data set of consecutive patients, supporting generalizability of the proposed methodology.
No takes yet. Share an insight, caveat, or question.
Volleberg et al. (2026) conducted an observational in Coronary artery disease undergoing clinically indicated intracoronary optical coherence tomography (OCT) (n=100). AI-based automated OCT full-vessel segmentation algorithm (OCT-AID) vs. Manual OCT image analysis by expert readers (consensus reference standard and interobserver variability) was evaluated on Frame-level agreement for calcified plaque identification between AI algorithm and expert consensus vs interobserver agreement (Kappa 0.88 vs 0.90, 95% CI 0.84-0.92, p=0.022). OCT-AID automated OCT segmentation achieved excellent agreement with expert consensus for calcified plaque and outperformed interobserver agreement for lipid plaque.
Synapse has enriched 10 related papers. Consider them for comparative context: