The behaviour of timber box-section supports and timber-concrete composite supports was investigated for potential application in an integrated composite structural system. A total of 23 specimens with full-scale cross-sections and lengths between 1.35 and 1.45 meters were tested. Seven different specimen types were analysed, including three distinct timber-concrete shear connection solutions. The timber box-section supports exhibited high load-bearing capacity under pin-ended conditions, demonstrating their viability for use as permanent formwork and structural supports during the concrete pouring and curing phases. The load-bearing capacity of the timber-concrete composite supports demonstrated a critical dependence on the shear connection pattern utilized. The connection pattern proposed by the authors successfully developed a confinement effect on the concrete core of the composite supports. Together with the resistance of the timber box-section, this effect increased the load capacity to 1.57 times that of the reinforced concrete core alone.
No takes yet. Share an insight, caveat, or question.
Otero-Chans et al. (2026) studied this question.