Resonant microcantilevers (MCs) are used for mass sensing, but their performance depends on the beam material and the surrounding medium. This paper presents a study of a self-actuating, self-sensing piezoelectric MC with a non-uniform geometry and a multilayer graphene platelet-reinforced composite (GPLRC) host structure. The model, based on Euler–Bernoulli beam theory and Hamilton’s principle, includes the hydrodynamic loading of the liquid and uses the output current of the piezoelectric layer as the sensing signal. It was validated against experimental data in air and in water–glycerol mixtures, with deviations of about 2% in frequency in air and below 5.1% in liquids. The relative current change ΔI/I caused by a 20 ng nanoparticle was evaluated for four GPL distribution patterns, three polymer matrices (epoxy, polyamide 6, and polypropylene), and different GPL contents and liquids. In air, ΔI/I reaches about 22% under the baseline conditions, whereas in water it is about one order of magnitude smaller (1.1–2.4%). The O-GPLRC pattern gave the highest sensitivity in both media, while the matrix had only a small effect. A Sobol sensitivity analysis showed that the GPL width and thickness dominate the variance of ΔI/I, whereas the GPL length contributes only 2–5%.