Resonant microcantilevers are widely used for mass sensing, yet the effects of material architecture and operating medium remain unclear. This study develops an analytical model of a multilayer graphene nanoplatelet-reinforced composite (GPLRC) piezoelectric microcantilever with a narrowed tip. The formulation combines Euler–Bernoulli beam theory, a modified Halpin–Tsai model, a piecewise modal solution incorporating adsorbed mass, and a string-of-spheres hydrodynamic model. Uniform (U) and functionally graded (X, O, A) platelet distributions are investigated in epoxy, polyamide 6 (PA6), and polypropylene (PP) matrices. Validation against published measurements yields deviations of 2.2% in air and 0.3–2.3% in liquids. Adsorption of a 20ng particle decreases resonance frequency. The relative shift in water is nearly ten times smaller than in air and decreases with increasing glycerol concentration. O-GPLRC produces the largest frequency shift in both media. PP performs best in air, whereas PA6 performs best in liquids. Amplitude-based responses rank configurations differently from frequency-based metrics. Higher platelet content reduces relative frequency shifts through stiffening. Sobol’ analysis identifies platelet width and thickness as dominant parameters, contributing 52–54% and 41–44% of variance, respectively, while length contributes less than 5%. These findings support optimizing material architecture, matrix, medium, and readout metric.