Key result
Tomek ventricular model increases inter-layer APD80 by ~35% with rate slowing, outperforming TT2.
Why the study?
The predictive behavior of cardiac digital twins depends strongly on the selected ionic model and the representation of transmural electrophysiological heterogeneity.
Does the Tomek ionic model differ from the ten Tusscher-Panfilov (TT2) model in simulating rate-dependent action potential duration (APD80) and transmural repolarization gradients across single-cell and 3D patient-specific ventricular models?
Does the Tomek ionic model differ from the ten Tusscher-Panfilov (TT2) model in simulating rate-dependent action potential duration (APD80) and transmural repolarization gradients across single-cell and 3D patient-specific ventricular models?
Tissue-level electrotonic coupling in 3D cardiac digital twins substantially reshapes single-cell rate-dependent action potential duration and transmural dispersion profiles, demonstrating critical fidelity differences between the TT2 and Tomek ionic models.
Answers are grounded in this paper and cite their sources.
Tomek versus TT2 choice markedly alters simulated rate-dependent repolarization in 3D models; leaves open optimal formulation for clinical digital twins.
Cardiac digital twins (CDTs) provide a computational platform for personalized cardiac modeling, but their predictive behavior depends strongly on the selected ionic model and the representation of transmural electrophysiological heterogeneity. In this study, we developed a multiscale CDT validation framework that integrates physiologically optimized hierarchical configurations. Using single-cell (0D) models and three-dimensional (3D) patient-specific ventricular models, we implemented the ten Tusscher-Panfilov model (TT2) and Tomek ionic model and compared their electrophysiological responses across a range of pacing frequencies, with basic cycle lengths (BCLs) from 600 to 4000 ms. The results show that tissue-level electrical coupling substantially reshapes the intrinsic dynamical properties observed at the single-cell level. By benchmarking model outputs against clinical data, this study quantifies fidelity differences between the two ionic models across multiple scales and provides a scientific basis for ionic model selection and CDT construction.
No takes yet. Share an insight, caveat, or question.
Fu et al. (2026) studied Myocardial Infarction. Tomek human ventricular ionic model vs. ten Tusscher-Panfilov (TT2) human ventricular ionic model was evaluated on Mean inter-layer action potential duration at 80% repolarization (APD80) in 3D ventricular model at BCL 4000 ms. In 3D ventricular models, the Tomek model increased mean inter-layer APD80 by 35.11% from BCL 600 to 4000 ms, compared to 7.79% with the TT2 model.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: