Key result
Noninvasive CMR and CT show moderate-to-strong correlation with invasive balloon sizing for RVOT dimensions.
Why the study?
Multimodality imaging guides preprocedural planning prior to percutaneous pulmonary valve implantation (PPVI), prompting assessment of how noninvasive right ventricular outflow tract (RVOT) measurements on cardiac magnetic resonance imaging (CMR) and cardiac computed tomography (CT) correlate with catheterization laboratory balloon sizing.
Do noninvasive RVOT measurements using cardiac MRI and cardiac CT correlate with invasive balloon sizing prior to percutaneous pulmonary valve implantation?
Cohort
Do noninvasive RVOT measurements using cardiac MRI and cardiac CT correlate with invasive balloon sizing prior to percutaneous pulmonary valve implantation?
Noninvasive RVOT measurements via cardiac MRI and CT demonstrate moderate-to-good correlation with invasive balloon sizing, supporting their complementary use in preprocedural planning for percutaneous pulmonary valve implantation.
Answers are grounded in this paper and cite their sources.
Noninvasive RVOT measurements may aid PPVI planning; leaves open standardized multimodality protocols and outcome validation.
Right ventricular outflow tract (RVOT) dysfunction is common in repaired congenital heart defects resulting in right ventricular (RV) dilation and dysfunction. Emerging transcatheter options enable placement of a competent pulmonary valve, obviating the need for surgery. Multimodality imaging plays a key role in determining the type and timing of intervention prior to percutaneous pulmonary valve implantation (PPVI). The authors sought to assess correlation of noninvasive RVOT measurements with cardiac magnetic resonance imaging (CMR) and cardiac computed tomography (CT) with balloon sizing in the catheterization laboratory prior to PPVI. A retrospective review was performed on patients who had undergone PPVI with preprocedural CMR and cardiac CT scan. Three-dimensional multiplanar reconstruction (MPR) of the narrowest RVOT diameter on magnetic resonance angiography (MRA), whole heart sequence (WHS) images, and CT scan images were performed using commercially available software; balloon sizing prior to PPVI was recorded. Concordance correlation coefficients were used to assess agreement with the clinically acceptable limit between the modalities set at +/- 2 mm. Additionally, mean difference was used to quantify the difference in measurements among the 2 modalities. For maximal waist dimensions, correlation between MRA and WHS images with balloon sizing was 0.70 to 0.79, while correlation between CT scan and balloon sizing was 0.65 to 0.75. For minimal waist dimensions, correlation between MRA and WHS images was 0.72 to 0.82; correlation between CT scan and balloon sizing was 0.64 to 0.73. Cardiac CT and CMR are complementary modalities that provide essential information for preprocedural planning for PPVI.
No takes yet. Share an insight, caveat, or question.
Rao et al. (2026) conducted a cohort in Repaired congenital heart defects with right ventricular outflow tract (RVOT) dysfunction undergoing percutaneous pulmonary valve implantation (PPVI). Noninvasive RVOT measurements via 3D multiplanar reconstruction on cardiac magnetic resonance (MRA and whole heart sequence) and cardiac CT vs. Invasive balloon sizing in the cardiac catheterization laboratory prior to PPVI was evaluated on Agreement and correlation of noninvasive RVOT measurements (maximal and minimal waist dimensions) with invasive balloon sizing (clinically acceptable limit set at +/- 2 mm) (CCC 0.70-0.79 (MRA/WHS vs balloon) and 0.65-0.75 (CT vs balloon) for maximal waist). Noninvasive CMR and CT RVOT measurements correlated with balloon sizing for maximal and minimal waist dimensions.