Answers are grounded in this paper and cite their sources.
State-of-health (SOH) estimation from short measurement windows can reduce reliance on complete charge or discharge cycles, but its reliability requires evaluation across unseen batteries, operating-condition shifts, and embedded hardware. This study evaluates SOH estimation from a nominal 10 s resampled voltage, current, and temperature window using NASA battery data. The window contained a median of one raw measurement, and approximately 90.9% of grid positions were interpolated. The 10 s duration denotes input width; actual onset-to-decision time was 15 s + δ (median: 21.812 s; 95th percentile: 29.016 s). Two Random Forest (RF) models were compared using strict leave-one-battery-out validation across 34 cells and adaptation-free condition holdouts. RF20x7 achieved a battery-macro mean absolute error of 7.096 percentage points versus 7.202 for RF150. The paired difference (−0.106 percentage points; 95% CI: −0.478 to +0.275) did not establish superiority, and equivalence was not tested. In the temperature-family holdout, RF20x7 reached 13.990 percentage points, a +6.997-point increase over the matched 31-cell reference. On an ESP32-C6, mean RF inference required 62.302 µs, while feature extraction and inference required 584.141 µs on pre-resampled inputs. These results support post-resampling computational feasibility but highlight reduced accuracy under unseen conditions.
No takes yet. Share an insight, caveat, or question.
İşlek et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: