Answers are grounded in this paper and cite their sources.
Smart waste management needs fill-level sensing that is accurate, affordable and reported in a reproducible way. This paper presents an IoT-enabled smart waste management system (SWMS) designed for the Special Economic Zone at Duqm (SEZAD), Oman, built around an Arduino Uno node with ultrasonic fill-level sensing, load-cell weighing, GPS and GSM communication. It reports a bench validation of the ultrasonic sensing, a partial component-level cost and a datasheet-based power estimate. Fourteen readings of an HC-SR04 sensor were taken around the 80% alert threshold (13.2 cm); ten fell in the alert region, with a mean of 13.38 cm (SD 0.37 cm; 95% CI 13.11–13.65 cm). Ranging accuracy was 99.37% (95% CI 98.59–100%) over the six readings nearest the threshold and 97.88% (95% CI 96.29–99.47%) over all ten, and all 14 alert decisions were correct (95% Wilson interval 78.5–100%). These values come from one sensor unit in a single run and are set beside three published accuracy figures (95.00–97.16%) whose protocols are not stated, so the comparison is indicative only. The priced bill of materials (USD 75.14 per bin) is partial, and the 3.3 W power figure is calculated from component ratings, not measured. A critical review of 21 studies identifies gaps in measurement-protocol reporting, multi-objective evaluation and field validation.
No takes yet. Share an insight, caveat, or question.
Yarubi et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: