Key result
Triplane echocardiography matches RT-3DE for detecting LV systolic dysfunction, achieving ~97% sensitivity.
Why the study?
With growing reliance on real-time three-dimensional echocardiography to assess LV systolic function in coronary and valvular heart disease, the accuracy of linear M-mode and volumetric biplane and triplane methods against RT-3DE required evaluation.
How accurate are linear M-mode, biplane, and triplane echocardiographic methods compared to real-time three-dimensional echocardiography in assessing left ventricular systolic function in patients with coronary and valvular heart disease?
Cross-Sectional (n=60)
No
How accurate are linear M-mode, biplane, and triplane echocardiographic methods compared to real-time three-dimensional echocardiography in assessing left ventricular systolic function in patients with coronary and valvular heart disease?
Real-time 3D and triplane echocardiography provide superior accuracy over traditional linear M-mode and biplane methods for assessing left ventricular ejection fraction in coronary and valvular heart disease.
Answers are grounded in this paper and cite their sources.
Linear and volumetric echo methods need further validation vs RT-3DE before clinical adoption; leaves open optimal technique for LV systolic assessment.
BACKGROUND:More dependence on real-time three dimensional echocardiography, is in practice in the assessment of LVsystolic function in coronary and valvular heart disease.OBJECTIVE:To investigate the accuracy of linear M-MODE and volumetric (BIPLANE and TRIPLANE)echocardiographic method versus the REAL-TIME 3DE in assessment of regional and global LV systolicfunction (depending on the high agreement of RT -3DE with CMR which is the gold standard inassessment of LV systolic function) and to start orientation to this issue in our centers.PATIENTS AND METHOD:This study included 60 patients with coronary heart disease and valvular heart disease who wereadmitted in Iraqi center for cardiac disease, for whom the LV systolic function is assessed by EF% byusing 3 methods which are M-mode, biplane, triplane methods and compare it with RT-3Dechocardiography.RESULTS:There is a significant difference between RT-3D echocardiography and old measures, (M-mode ,sensitivity and specificity was 74.3% , 95.2% respectively) and that of (Biplane was 97.4%, 95.2%respectively ), while there is no significant difference with triplane method in the assessment of LVsystolic dysfunction by EF% in coronary and valvular heart disease as it was (97.4% , 100% respectively)CONCLUSION:Real-time three dimensional echocardiography provides more valuable and accurate clinical informationthat empowers echocardiographers with new levels of confidence in the diagnosis of LV systolicdysfunction in coronary and valvular cardiac disease.
No takes yet. Share an insight, caveat, or question.
Abid et al. (2025) conducted a cross-sectional in Coronary heart disease and valvular heart disease (n=60). Linear M-mode, biplane, and triplane echocardiography vs. Real-time three-dimensional echocardiography (RT-3DE) was evaluated on Accuracy in assessment of regional and global left ventricular systolic function (LVEF%). Triplane echocardiography showed no significant difference compared to RT-3DE for LV systolic dysfunction, whereas M-mode had 74.3% sensitivity.
Synapse has enriched 10 related papers. Consider them for comparative context: