Answers are grounded in this paper and cite their sources.
This study investigates the bond performance of titanium alloy (TiA) bars in near-surface mounted (NSM) concrete strengthening systems, with carbon fiber-reinforced polymer (CFRP) bars included for comparison. Twenty-seven C-shaped concrete specimens were tested under pull-out loading to examine the effects of bar type, bar diameter ( d b ), bonded length, and adhesive type. TiA bars exhibited diverse failure modes, with 10 mm bars failing by yielding or pull-out depending on bonded length and adhesive type, whereas the 16 mm specimens failed prematurely by concrete splitting, limiting full bond mobilization and providing lower-bound system responses. In contrast, CFRP bars consistently failed through epoxy cover splitting without bar rupture. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) analyses were employed to characterize interfacial failure mechanisms at the microstructural level. For the 10 mm TiA bars, increasing bonded length from 6 d b to 12 d b increased bond capacity, though a further extension to 24 d b showed diminishing returns. At 12 d b , CFRP bars developed higher average bond stress than TiA bars; however, this observation reflects differences in governing failure modes rather than actual interfacial bond strength. At 6 d b , TiA bars developed higher average bond stress than CFRP bars, which may be associated with the mechanical interlock provided by their pseudo-threaded surface profile. Among the adhesives, NSM-Gel (NG) epoxy consistently outperformed Sikadur-30 LP (SK) epoxy for the tested 10 mm TiA bars, consistent with the distinct mechanical properties of the two epoxy adhesives. TiA bars reached the yield load with NG epoxy at bonded lengths of 12 d b and 24 d b , whereas CFRP bars reached up to 65% of their ultimate tensile capacity within the tested configurations. Among the evaluated analytical models, the Malvar bond–slip model provided the highest overall R ², whereas the modified Bertero–Popov–Eligehausen (BPE) model more closely reproduced the terminal post-peak response. The findings provide valuable insights for the design and optimization of NSM systems using both metallic and composite reinforcements.
No takes yet. Share an insight, caveat, or question.
Al-Ghanim et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: