Answers are grounded in this paper and cite their sources.
In a fluid catalytic cracking (FCC) regenerator, the gas flow rate is a main parameter which influences on the catalyst concentration distribution, the catalyst circulation rate and the product yield. Eulerian-Eulerian model incorporated the kinetic theory of granular flows is employed to the Computational fluid dynamics (CFD) simulation in the three-dimensional region. In order to save time and improve accuracy, this study aims to simulate the gas–solid mixture flows for FCC process using flue gas composition for fluidizing gas without coke combustion reaction. The variation of quantities such as gas velocity, solid velocity vectors, catalyst content and catalyst concentration versus axial height are discussed to reflect the effect of fluidizing gas flow rate. Simulation results using the flue gas as the fluidizing gas are in closer agreement with the plant data in comparison to the air-simulation.
No takes yet. Share an insight, caveat, or question.
Pak et al. (2026) studied this question.