Key result
Balloon-type pulmonary artery configuration had a higher rate of postnatal artificial ventilation and poorer survival prognosis than clover-type PA in TF/APV.
Why the study?
Tetralogy of Fallot with absent pulmonary valve (TF/APV) is a rare and severe congenital heart disease with high mortality. This study aimed to assess whether TF/APV prognosis relates to fetal and postnatal clinical course and pulmonary artery (PA) configuration.
Are fetal/postnatal clinical factors and pulmonary artery configuration associated with survival and need for postnatal artificial ventilation in patients with tetralogy of Fallot with absent pulmonary valve?
Cohort (n=13)
Are fetal/postnatal clinical factors and pulmonary artery configuration associated with survival and need for postnatal artificial ventilation in patients with tetralogy of Fallot with absent pulmonary valve?
Answers are grounded in this paper and cite their sources.
In tetralogy of Fallot with absent pulmonary valve, patent ductus arteriosus and clover-type pulmonary artery configuration are associated with survival, whereas polyhydramnios, hydrops fetalis, and balloon-type main PA expansion predict poor postnatal prognosis and ventilation need.
BACKGROUND: Tetralogy of Fallot with absent pulmonary valve (TF/APV) is a rare and severe congenital heart disease with high mortality. The aim of this study was to assess whether TF/APV prognosis is related to fetal and postnatal clinical course and pulmonary artery (PA) configuration. METHODS: The fetal and postnatal echocardiograms and clinical outcomes of 13 patients with TF/APV (diagnosed antenatally in 9 patients and postnatally in 4) were reviewed, and divided into two groups: group A (n = 6), alive; and group D (n = 7), dead. RESULTS: Fetal period: group A, polyhydramnios n = 0, hydrops fetalis (HF) n = 0, patent ductus arteriosus (PDA) n = 2; group D, polyhydramnios n = 3, HF n = 2, PDA n = 0. Postnatal period: group A, five patients underwent intracardiac repair, including one requiring artificial ventilation (AV). A further AV patient required three operations before extubation. Postoperative courses were all good. Group D, excluding the two intrauterine fetal deaths, four patients required AV (three of whom died neonatally or in early childhood) and one underwent intracardiac repair. PA configuration: all group A patients had bulbous expansion of left and right PA (clover type). Three patients in group D had bulbous expansion of main PA (balloon type). CONCLUSIONS: PDA was a factor associated with good prognosis. Hydramnion and HF were factors associated with poor prognosis. Given that there was a higher rate of postnatal AV and poorer prognosis in balloon type than in clover type PA (P < 0.05), PA configuration is also considered an important factor to predict postnatal outcome in TF/APV.
No takes yet. Share an insight, caveat, or question.
Kawazu et al. (2014) conducted a cohort in Tetralogy of Fallot with absent pulmonary valve (TF/APV) (n=13). Balloon-type pulmonary artery configuration (bulbous expansion of main PA) and fetal risk factors (polyhydramnios, hydrops fetalis, absent PDA) vs. Clover-type pulmonary artery configuration (bulbous expansion of left and right PA) and presence of patent ductus arteriosus was evaluated on Survival (alive vs. dead) and postnatal artificial ventilation requirement (p=<0.05). Balloon-type pulmonary artery configuration had a higher rate of postnatal artificial ventilation and poorer survival prognosis than clover-type PA in TF/APV.
Synapse has enriched 10 related papers. Consider them for comparative context: