Key result
Reverse thermosensitive gel intracoronary shunt sealing halts bleeding without blower use across 19 anastomoses.
Why the study?
The efficacy of a reverse thermosensitive gel (poloxamer P407) for intracoronary shunt sealing during off-pump coronary artery bypass surgery to stop residual bleeding and avoid blower use needed to be evaluated.
Does intracoronary shunt sealing with a reverse thermosensitive gel (poloxamer P407) stop residual bleeding and avoid blower use in patients undergoing off-pump coronary artery bypass surgery?
Observational (n=5)
Does intracoronary shunt sealing with a reverse thermosensitive gel (poloxamer P407) stop residual bleeding and avoid blower use in patients undergoing off-pump coronary artery bypass surgery?
Intracoronary shunt sealing with poloxamer P407 reverse thermosensitive gel effectively controlled bleeding and eliminated the need for blower use during off-pump coronary artery bypass surgery without operative or 4-month complications in a 5-patient feasibility series.
Answers are grounded in this paper and cite their sources.
May support blower-free anastomoses in off-pump CABG; leaves open safety and efficacy in larger trials.
OBJECTIVE: : To check the efficacy of a reverse thermosensitive gel (poloxamer P407) for intracoronary shunt sealing in off-pump coronary artery bypass surgery to stop residual bleeding from the shunt and avoid the use of blowers. METHODS: : Nineteen coronary anastomoses were performed on five patients who underwent off-pump coronary artery bypass surgery. Intracoronary shunting was adopted in all procedures. All the shunts were sealed into the coronary lumen with the injection of a reverse thermosensitive gel. Before tying the sutures, a piece of ice was applied on the anastomotic sites to dissolve the gel. Bleeding from the coronary lumen was always checked after shunt removal. RESULTS: : Bleeding was stopped or reduced and anastomoses performed without blower use. In one case, bleeding started again after shunt manipulation, and the shunt sealing procedure needed to be repeated. No intraoperative surface electrocardiogram and regional motion changes were detected. All patients showed normal creatine kinase-MB (CK-MB) levels in the postoperative period. All patients were free from adverse cardiovascular events at 4 months from operation. CONCLUSIONS: : The use of a thermosensitive polymer for intracoronary shunt sealing was effective in controlling bleeding, eliminated the necessity for blower use, and was not associated to operative complications.
No takes yet. Share an insight, caveat, or question.
Lemut et al. (2010) conducted an observational in Off-pump coronary artery bypass surgery (n=5). Reverse thermosensitive gel (poloxamer P407) for intracoronary shunt sealing was evaluated on Residual bleeding from the shunt and need for blower use. Reverse thermosensitive gel (poloxamer P407) for intracoronary shunt sealing stopped or reduced bleeding without blower use in 19 anastomoses (5 patients), with 0% adverse events at 4 months.
Synapse has enriched 10 related papers. Consider them for comparative context: