Answers are grounded in this paper and cite their sources.
The thermal performance of the conventional solar air heater (SAH) was constrained by its heat transfer area. This work presents an experimental exergy and energy analysis for an innovative SAH with a flat absorber plate incorporating multiple rear air channels to increase the surface area of the heat transfer without increasing frontal area. Three identical collectors (dimensions: 110 cm × 85 cm × 8 cm) were tested under real outdoor conditions at tilt angles of 20°, 30°, and 45°, respectively. Each collector included a distinct design for an absorber plate: Model 1 – the conventional flat plate; Model 2 – an absorber with square pipes; and Model 3 – the proposed absorber configuration. The analysis results demonstrated that the SAH inclined at 30° achieved average heat‐gain increases of 7.24% and 14.17% for Models 2 and 3, respectively, compared to Model 1. Furthermore, tilting Model 3 by 30° attained average overall thermal and exergy efficiencies of 32.67% and 27.3%, with an improvement index of 28.34. This indicated that increasing the heat‐transfer area in Model 3 is approximately two times more effective than modifying the absorber in Model 2. Also, it confirmed that the innovative configuration achieved a significant improvement in the convective heat transfer rate.
No takes yet. Share an insight, caveat, or question.
Resen et al. (2026) studied this question.