Key result
Transcatheter Cocoon duct occluder closure successfully seals a postpartum ruptured sinus of Valsalva aneurysm.
Why the study?
Rupture of a sinus of Valsalva aneurysm is uncommon and may be associated with acute haemodynamic deterioration, with cardiovascular changes of labour and delivery potentially contributing to the rupture of an undiagnosed aneurysm.
Case Report (n=1)
No
This case report demonstrates the feasibility and success of transcatheter device closure using a duct occluder for a ruptured sinus of Valsalva aneurysm presenting as acute postpartum heart failure.
Answers are grounded in this paper and cite their sources.
Supports feasibility of transcatheter duct occluder closure for postpartum ruptured sinus of Valsalva aneurysm; leaves open need for prospective validation before wider adoption.
Background: Rupture of a sinus of Valsalva aneurysm is uncommon and may be associated with acute haemodynamic deterioration. The cardiovascular changes of labour and delivery may contribute to the rupture of an undiagnosed aneurysm. This report describes a postpartum presentation after an uncomplicated vaginal delivery and subsequent transcatheter management. Case presentation: A 28-year-old multiparous woman developed sudden chest pain and progressive dyspnoea immediately after an uncomplicated vaginal delivery. Examination identified tachycardia, bounding peripheral pulses, raised jugular venous pressure and a continuous murmur. Transthoracic echocardiography demonstrated a 7-mm rupture originating from the right coronary sinus and communicating with the right ventricular outflow tract, producing continuous left-to-right shunting. Aortography confirmed the anatomical findings. The patient initially received diuretics and standard heart failure therapy; however, her symptoms persisted. On the eighth postpartum day, transcatheter closure was undertaken using a 14/12 mm Cocoon duct occluder under fluoroscopic and echocardiographic guidance. Completion angiography showed closure without residual shunting or new aortic regurgitation, with preserved right coronary artery flow. Symptoms resolved after the procedure, and she was discharged on the third post-procedure day. She remained asymptomatic at three-month follow-up. Conclusion: This case illustrates the importance of considering ruptured sinus of Valsalva aneurysm in postpartum heart failure when clinical examination suggests an abnormal intracardiac shunt. Transcatheter closure was feasible in this patient after stabilisation and assessment of anatomical suitability.
No takes yet. Share an insight, caveat, or question.
Jain et al. (2026) conducted a case report in Ruptured sinus of Valsalva aneurysm (n=1). Transcatheter closure using a 14/12 mm Cocoon duct occluder was evaluated on Aneurysm closure and symptom resolution. Transcatheter closure with a 14/12 mm Cocoon duct occluder successfully sealed a 7-mm postpartum ruptured sinus of Valsalva aneurysm with complete symptom resolution at 3 months.
Synapse has enriched 10 related papers. Consider them for comparative context: