Key result
Total endovascular aortic arch repair achieves ~95% technical success but carries up to ~11% stroke risk.
Why the study?
What are the technical success rates and clinical outcomes of contemporary total endovascular aortic arch reconstruction platforms in high-risk patients?
What are the technical success rates and clinical outcomes of contemporary total endovascular aortic arch reconstruction platforms in high-risk patients?
Contemporary total endovascular aortic arch repair platforms demonstrate high technical success (90-100%) in high-risk patients, though stroke (3.7-11%), endoleaks, and reinterventions require careful patient and device selection.
Answers are grounded in this paper and cite their sources.
Variable stroke rates warrant cautious selection; leaves open durability and optimal platform choice for prospective trials.
Endovascular technologies offer less invasive alternatives to open aortic arch repair in high-risk patients. This review evaluates contemporary total arch reconstruction platforms. PubMed literature through February 2026, manufacturer documentation, and ClinicalTrials.gov were reviewed. Branched, fenestrated, and alternative devices were assessed regarding anatomy, procedural characteristics, and clinical outcomes. No formal systematic review or meta-analysis was performed. Technical success rates reached 90-100%. Branched devices enable three-vessel revascularization, while fenestrated systems accommodate complex anatomy. Stroke rates ranged from 3.7% to 11%; endoleaks and reinterventions remained concerns. To date, anyway, device selection, anatomical suitability, planning, and institutional expertise are essential for optimal outcomes.
No takes yet. Share an insight, caveat, or question.
Macchio et al. (2026) conducted a review in Aortic arch pathology requiring repair in high-risk patients. Total endovascular aortic arch repair (branched, fenestrated, and alternative devices) vs. Open aortic arch repair (conceptual; narrative review) was evaluated on Technical success and stroke rates. Total endovascular aortic arch repair achieved technical success rates of 90-100%, with stroke rates ranging from 3.7% to 11% across reviewed platforms.
Synapse has enriched 10 related papers. Consider them for comparative context: