Why the study?
There was a paucity of evidence on the impact of anticoagulation after bioprosthetic aortic valve replacement on valve hemodynamics and clinical outcomes.
Population
4,832 patients undergoing bioprosthetic AVR (3,889 TAVR and 943 SAVR) in PARTNER2 cohorts
Comparison
Patients discharged on anticoagulation vs those not discharged on anticoagulation
Design
Pooled cohort analysis of PARTNER2 randomized trials and nonrandomized registries
Follow-up
1 year
Answers are grounded in this paper and cite their sources.
May support individualized anticoagulation post-bioprosthetic AVR; leaves open definitive guidance pending randomized evidence.
BACKGROUND There is paucity of evidence on the impact of anticoagulation (AC) after bioprosthetic aortic valve replacement (AVR) on valve hemodynamics and clinical outcomes. OBJECTIVES The study aimed to assess the impact of AC after bioprosthetic AVR on valve hemodynamics and clinical outcomes. METHODS Data on antiplatelet and antithrombotic therapy were collected. Echocardiograms were performed at 30 days and 1 year post-AVR. Linear regression model and propensity-score adjusted cox proportional model were used to assess the impact of AC on valve hemodynamics and clinical outcomes, respectively. RESULTS A total of 4,832 patients undergoing bioprosthetic AVR (transcatheter aortic valve replacement [TAVR], n = 3,889 and surgical AVR [SAVR], n = 943) in the pooled cohort of PARTNER2 (Placement of Aortic Transcatheter Valves) randomized trials and nonrandomized registries were studied. Following adjustment for valve size, annular diameter, atrial fibrillation, and ejection fraction at the time of assessment of hemodynamics, there was no significant difference in aortic valve mean gradients or aortic valve areas between patients discharged on AC vs. those not discharged on AC, for either TAVR or SAVR cohorts. A significantly greater proportion of patients not discharged on AC had an increase in mean gradient >10 mm Hg from 30 days to 1 year, compared with those discharged on AC (2.3% vs. 1.1%, p = 0.03). There was no independent association between AC after TAVR and adverse outcomes (death, p = 0.15; rehospitalization, p = 0.16), whereas AC after SAVR was associated with significantly fewer strokes (hazard ratio [HR]: 0.17; 95% confidence interval [CI]: 0.05-0.60; p = 0.006). CONCLUSIONS In the short term, early AC after bioprosthetic AVR did not result in adverse clinical events, did not significantly affect aortic valve hemodynamics (aortic valve gradients or area), and was associated with decreased rates of stroke after SAVR (but not after TAVR). Whether early AC after bioprosthetic AVR has impact on long-term outcomes remains to be determined. (Placement of AoRTic TraNscathetER Valves [PARTNERII A]; NCT01314313).
No takes yet. Share an insight, caveat, or question.
Chakravarty et al. (2019) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: