Key result
Refined screening and smaller sheaths in transfemoral PAVR linked to an absolute ~7% drop in major vascular complications.
Why the study?
Vascular complications are the major cause of mortality and morbidity associated with PAVR, and both open surgical and fully percutaneous access site strategies have been advocated. This study evaluated vascular complications in transfemoral PAVR using current Valve Academic Research Consortium definitions.
Does the increasing use of smaller sheaths, rigorous screening/patient selection, and percutaneous vascular repair techniques reduce vascular and bleeding complications in patients undergoing transfemoral percutaneous aortic valve replacement?
Cohort (n=137)
Does the increasing use of smaller sheaths, rigorous screening/patient selection, and percutaneous vascular repair techniques reduce vascular and bleeding complications in patients undergoing transfemoral percutaneous aortic valve replacement?
Answers are grounded in this paper and cite their sources.
In patients undergoing transfemoral percutaneous aortic valve replacement, careful patient selection via angiographic and CT screening, smaller sheaths, and fully percutaneous pre-closure techniques significantly reduced minor vascular complications, major bleeding, and unplanned vascular surgery from 2009 to 2010.
Objectives The aim of this study was to evaluate vascular complications in a consecutive patient population undergoing transfemoral percutaneous aortic valve replacement (PAVR) applying current Valve Academic Research Consortium definitions. Background Vascular complications have been the major cause of mortality and morbidity associated with PAVR. Both open surgical and fully percutaneous access site strategies have been advocated. Methods All patients undergoing transfemoral PAVR during fiscal years 2009 and 2010 were prospectively evaluated at baseline, after the procedure, and at 30 days. Results PAVR was performed in 137 consecutive patients. All but 1 patient underwent planned arteriotomy closure using a percutaneous pre-closure technique. Smaller sheaths, rigorous angiographic and computed tomographic screening and patient selection, and percutaneous vascular repair techniques were increasingly used over this period. From 2009 to 2010, major vascular complications decreased from 8% to 1% (p = 0.06), minor vascular complications decreased from 24% to 8% (p < 0.01), major bleeds fell from 14% to 1% (p < 0.01), and unplanned surgery decreased from 28% to 2% (p < 0.01). A minimal artery diameter smaller than the external sheath diameter, moderate or severe calcification, and peripheral vascular disease were associated with higher vascular complication rates. Conclusions Vascular complications occur more often if the minimal artery diameter is smaller than the external sheath diameter, in the presence of moderate or severe calcification, and in patients with peripheral vascular disease. With careful patient selection, advanced interventional techniques, and a fully percutaneous procedure, marked reductions in vascular and bleeding complications can be achieved.
No takes yet. Share an insight, caveat, or question.
Toggweiler et al. (2012) conducted a cohort in Aortic valve disease undergoing transfemoral percutaneous aortic valve replacement (PAVR) (n=137). Transfemoral percutaneous aortic valve replacement (PAVR) in fiscal year 2010 (with smaller sheaths, rigorous screening, and percutaneous repair) vs. Transfemoral PAVR in fiscal year 2009 was evaluated on Major vascular complications (Valve Academic Research Consortium definitions) (p=0.06). Transfemoral PAVR with refined screening and smaller sheaths from 2009 to 2010 reduced major vascular complications from 8% to 1% and minor complications from 24% to 8%.
Synapse has enriched 10 related papers. Consider them for comparative context: