Answers are grounded in this paper and cite their sources.
flake and found that the irradiated region exhibited an enhanced PL relative to the pristine region. Pump-probe signals were then acquired by raster-scanning across both regions by a pair of galvanometer scanners, providing identical excitation and detection conditions for direct comparison of their ultrafast dynamics between the doped and pristine regions. Tri-exponential fits to the pump-probe dynamics show that the slow decay component, assigned to the radiative recombination of neutral A excitons, shortens from an average of 115 ps in the pristine region to 84 ps in the CT-doped region. The radiative recombination rate is estimated to be about 4 times the rate in the pristine area due to the enhanced exciton oscillator strength, a consequence of reduced Pauli blocking and coulombic screening. Further quantitative analysis identifies the increased radiative recombination rate as the primary cause of the PL improvement. These results elucidate the ultrafast exciton dynamics underlying CT-doping-induced PL enhancement in TMDs under high excitation powers and offer guidance for designing high-performance optoelectronic devices based on 2D materials.
No takes yet. Share an insight, caveat, or question.
Shen et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: