Answers are grounded in this paper and cite their sources.
Following the amendment of the International Code for the Construction and Equipment of Ships Carrying Liquefied Gases in Bulk (IGC Code) permitting cargo to be used as fuel, ammonia-fueled ammonia carriers are expected to enter service, requiring safety criteria for ammonia releases. To provide a quantitative basis for such criteria, computational fluid dynamics (CFD) dispersion analyses of this rarely studied ship type were performed using FLACS for vent mast releases from the pressure safety valve (PSV) of the fuel service tank under external fire and from purging after an engine emergency shutdown, and for fan discharge after a pipeline leak in the fuel preparation room. Lacking ammonia engine data, the purge release was estimated from liquefied petroleum gas (LPG) engine data on a lower-heating-value basis. The 10-min time-weighted average (TWA) concentration at the accommodation area was about 920 ppm for the PSV release, exceeding the Acute Exposure Guideline Level 2 (AEGL-2), 156 ppm for the purge, exceeding AEGL-1, and about 13 ppm for the preparation room leak. Pre-discharge treatment was the most effective mitigation, and the purge exceeded AEGL-1 for ±50% of the estimated release rate. The results support criteria requiring pre-discharge treatment, combined time-averaged and instantaneous limits, and verification over the operating speed range.