Answers are grounded in this paper and cite their sources.
In industrial HVAC applications, air distribution duct velocity and diffuser blade geometry determine the distribution and velocity uniformity of the supply air within the process zone. In this study, the air distribution duct in the roving hall of a ring-spinning mill was examined under different inlet conditions. Using Ansys Fluent 2024 R1 version, the velocity distributions within the air distribution duct and in the diffusers were investigated for inlet velocities of 12, 14, and 16 m/s using the k-ε standard, k-ω standard, and k-ω SST turbulence models. Furthermore, the air velocity and turbulent kinetic energy distributions on the diffuser surface were evaluated for five different vertical blade angles (α = 15°, 30°, 45°, 60°, and 75°). In the numerical analyses, actual measurement data obtained from the facility were compared with analyses found in the literature, and the agreement of the airflow values was determined. The results show that increasing the inlet velocity does not proportionally increase flow velocity. The k-ω SST model provides more realistic results in capturing flow separation caused by reverse pressure gradients because it takes into account boundary-layer dynamics near the wall. The analysis results revealed that, within the range where the air velocity at the duct inlet was 12–14 m/s, the air velocity within the duct increased by 21.1% in the k-ω SST model, exhibiting more pronounced variations compared with the k-ε standard (16.7%) and k-ω standard (16.6%) models. This indicates that the k-ω SST model is more sensitive to changes in wind speed. Analysis performed on the diffusers revealed a relationship between blade angle and wall friction, and it was determined that as the angle increased, the airflow velocity on the diffuser surfaces decreased. It has been observed that blade angles of 30° and 45° provide a more balanced airflow. From a blade angle of 45° onwards, due to the effect of flow separations, the turbulent kinetic energy was observed to be spread over wider areas on the diffuser outlet surfaces. At blade angles of 60° and 75°, sudden vortex formation and flow separations were found to maximize the magnitude and the spatial distribution of turbulent kinetic energy across the surface. This study presents an original parametric analysis based on a numerical model, which is compared against actual operational data (SCADA and digital anemometer measurements) with the aim of optimizing the efficiency and comfort conditions of air distribution ducts in industrial settings that require precise climate control.
No takes yet. Share an insight, caveat, or question.
AVCI et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: