Pure hydrogen–oxygen dead-ended anode–cathode PEMFCs (DEAC-PEMFCs) provide high reactant utilization and a compact system layout, making them attractive for confined-space applications. However, replacing air with pure oxygen as oxidant brings more challenging water management issues. To address this problem, a cascaded DEAC-PEMFC with counter-flow gas supply and integrated humidification is developed, and its multi-physics model coupling mass conservation, thermodynamics, and electrochemistry is established. A mixed-purge strategy combining time-based anode purging with voltage-triggered cathode purging is adopted. Based on this model, the effects of purge interval, purge duration, and inlet pressure on stack performance are respectively evaluated. The results show that a purge duration of 0.1 sec provides an effective balance between water removal and reactant utilization. At 200, 600, and 1000 mA cm−2, the optimal cathode purge intervals are 259.63, 126.82, and 30.97 sec, while the corresponding anode intervals are 200, 140, and 55 sec. The optimized strategy maintains both hydrogen and oxygen utilizations at approximately 99%, with a stack voltage coefficient of variation (CV) below 1%, indicating small relative voltage fluctuations.