Architectural wall panels excluded from a building’s designated seismic-force-resisting system may nevertheless alter lateral response through deformation compatibility. This study compares three representations of a 28-story reinforced-concrete building in Bangkok: load-and-mass-only walls (M1), stiffness-engaged exterior precast façade panels (M2), and M2 with a hypothetical interior-precast configuration (M3). Modal, code-based equivalent-lateral-force and response-spectrum, event-specific nonlinear response-history, and nonlinear pushover analyses were evaluated. Supplementary linear tests examined wall and slab flexural stiffness and in-plane diaphragm flexibility. Switching from rigid to semi-rigid diaphragms increased maximum equivalent-lateral-force X-direction interstory drift by 2.38%, 35.99%, and 37.98% for M1–M3, respectively. At matched roof displacements, common-force-distribution pushover analyses changed directional lateral base resistance by −9.58% to +11.44% relative to original modal-force analyses; loading histories and numerical controls were not completely matched. The originally derived building-specific response-modification indicators were 1.996/2.884, 9.020/4.956, and 3.092/4.717 (M1–M3, X/Y) but reflect nonuniform numerical terminal-state definitions, not independently verified global-collapse capacities. These results identify modeling-dependent trends and bound the interpretation of panel engagement and derived strength–deformation indicators.